EasyManua.ls Logo

Horton C2150 - Belt Drive Actuation and Autolock Setup; Configuring Belt Drive Actuation Modes; Belt Drive Autolock Initialization Procedures

Horton C2150
15 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
D
VERSIONTYPE
E
D
D
D
1.17
1.17
1.17
1.00
1.00
P1.02
1.00
P
P
P1.17
E
1.17P
PD
1.16
D
P
P
1.00
1.16
1.16
P
P
1.00
1.00
1.00
D
PD
1.00
PD
PD
P
D1.09
1.00
1.17D
PD 1.00
D1.17
E
1.00PD
PD
1.00
1.00
1.00
1.15
1.16
D
1.14
1.16DP
1.14D
D1.16
1.00
CODE
1.0016d
10/05
D1.17
D
1.00
Door is idle in
1
way
d
ay mode. See section 5
Door is idle in
1
way
n
ight mode. See section 5
Door is idle in
2
way
d
ay mode. See section 5
Door is idle in
2
way
n
ight mode. See section 5
Use only with APEX system - see APEX instruction G550
Use only with APEX system - see APEX instruction G550
Use only with APEX system - see APEX instruction G550
b
i stable
L
ock - no longer used
Power fail
CL
ose see section14
C
lose
S
peed see section 2 step 8
APEX communication error - if using APEX then turn AP on
C
lose
C
heck speed - see section 2, step 8
Use only with APEX system - see APEX instruction G550
P
H201C.10
1.02
This is a cycle code (see foot note ) from ext motec input see appendix D CN2
This is a cycle code (see foot note ) from
DOWN
button
Partial open delay is active when SW 'A' is on (App. D) & starts when all activate and recycle inputs have cleared & door is at partial open
APPENDIX B1 CODE DISPLAYS
Codes are arranged in alphanumeric order (NOTE: D = Display, P = Parameter, E = Error)
This shows a successful Data Save. See section 3 step 10
Control failed to store parameters (control must be replaced)
DISPLAY MEANING
D
oor
L
ocks (in day mode ) when this parameter is turned on. See section 7
Control has failed - must be replaced
To activate this APEX feature you must - turn the parameter on - do a data save, and then press reset only
This indicates battery failure of C3985 monitored power failure unit - see section 14
This parameter is factory set - do not change without consulting factory
Door idle in
dA
y mode.(Has been replaced in later software by1d or 2d parameter see section 5
Control is braking - door always brakes when opening. Close braking can be turned on at the parameter
When
A
uto
S
eal parameter is turned on, the display will change to
AS
and the control will try to close the door every 15 seconds
Determines how long control brakes motor after open speed
When
c
lose
b
raking parameter is turned on, the control brakes the door after close speed - recommended for heavy doors
Use only with APEX system - see APEX instruction G550
This parameter determines stroke to open check. Adjustable from 50-90% of total stroke
C
ycle
t
est will cause door to open and close repeatedly for test purposes
C
lose
C
ushion speed (see section 2 step 8)
Main time delay- starts when all activate and recycle inputs clear and door is fully open
Use only with APEX system - see APEX instruction G550
Door was activated or is being held open by SW 'C' input. See App. D CN2 for wiring & LED
B
rake on
r
ecycle turned on, the control will slow door substantially before reversing on recycle
Use only with APEX system - see APEX instruction G550