4 49-5000684 Rev. 1
ŶPOWER
3UHVVWKH32:(5EXWWRQWRWXUQWKHXQLWRQRURII:KHQ
the unit is on,the power indicator light will be green.
:KHQWKHXQLWLVRIIWKHOLJKWZLOOJRRXW
ŶMODE
3XVKWKLVEXWWRQWRF\FOHWKURXJKWKHPRGHVIURP&22/
+($7)$1'5<7KHLQGLFDWRUOLJKWEHVLGHWKH³02'(´
option will illuminate, identifying the mode selected.
COOL: The range of set temperature is 62°F~86°F.
Cooling begins automatically when the room
temperature is above the set point,and stops when the
URRPWHPSHUDWXUHLV)EHORZWKHVHWSRLQW%XWWKH
FRPSUHVVRUZLOOUXQDPLQLPXPRIPLQXWHVLQ&22/
mode before stopping. The fan is set up from the factory
to run in continuous mode when in cooling.
HEAT: The range of set temperature is 62°F~84°F.
For heat pump models the unit can alternate running
between reverse cycle heat mode and electric heater
mode according to the difference between the set
temperature and the room temperature. The fan motor
cycles on and off with the compressor and electric
heater.
The indoor fan motors starts before the compressor
and stops after the compressor cycles off.
NOTE: Reverse cycle heating and the electric heater
no not run at the same time. In the following cases, it
is normal that the compressor does not operate.
:KHQWKHRXWGRRUWHPSHUDWXUHLVORZHUWKDQ)RU
the room temperature falls to 8°F below the set point
temperature.
7RSUHYHQWVKRUWF\FOLQJWKHUHLVDPLQXWH
PLQLPXPFRPSUHVVRU2))WLPHEHWZHHQF\FOHV
:KHQIURVWEXLOGVXSWKHFRLOWKHFRPSUHVVRUZLOO
cycle off while the ID fan continues to run to defrost
the coil.
• FAN: Fan operation only without heating and cooling.
NOTE: The set temperature ranges can be changed.
6HH³',36:,7&+(6&21),*85$7,216RQSDJH 6
for details.
DRY:6HWVXQLWWR&RROPRGHDQGORZIDQVSHHGWRKHOS
with dehumidification.
ŶUP/DOWN BUTTONS ( + / - )
3XVKWKH83RU'2:1EXWWRQWRLQFUHDVHRUGHFUHDVH
the set temperature of the unit in cooling or heating
PRGH7KHWHPSHUDWXUHFDQEHVHWE\LQFUHPHQWVRI)
The set temperature appears in the display.
NOTE: 3UHVVDQGKROGWKH+ and - EXWWRQVWRJHWKHUIRU
seconds to change the temperature display between °C
& °F scale.
ŶFAN (FAN SPEED)
(YHU\WLPH\RXSXVKWKLVEXWWRQWKHIDQVSHHGF\FOHV
WKURXJKWKHVHWWLQJVDVIROORZV$872+,*+/2:
Ŷ&2167$17)$1
3URYLGHVFKRLFHRIRSHUDWLQJWKHLQGRRUIDQFRQWLQXRXVO\
RUF\FOLQJLWRQRIIZLWKWKHFRPSUHVVRU$IDQLFRQ
appears near the display when the fan is in constant
PRGH:KHQLQF\FOHPRGHWKHIDQZLOORSHUDWHIRU
several seconds after the compressor cycles off. This
VZLWFKLVQRWDFWLYHLQWKH+HDWPRGH
ŶDISPLAYS:
:KLOHLQ)DQRQO\PRGHLWVKRZVWKHURRPWHPSHUDWXUH
Control and Error code (on some models):
LC 3XVKEXWWRQVRQWKHFRQWUROSDQHODUHQRWDYDLODEOH
The unit can only be operated by using wall thermostat.
FC 3XVKEXWWRQVRQWKHFRQWUROSDQHODQGZDOO
thermostat are not available. The unit can only be
RSHUDWHGE\XVLQJ)5217'(6.&21752/
Error codes:
AS5RRPWHPSHUDWXUHVHQVRUHUURU
ES(YDSRUDWRUWHPSHUDWXUHVHQVRUHUURU
CS&RQGHQVHUWHPSHUDWXUHVHQVRUHUURU
OS2XWVLGHWHPSHUDWXUHVHQVRUHUURU
HS([KDXVWWHPSHUDWXUHVHQVRUHUURU
LE:LUHFRQWUROOHUHUURU
NOTE: :KHQHUURURFFXUVXQSOXJWKHXQLWDQGSOXJLW
back in.If error repeats, call for service.
2WKHUFRGHV
LO5RRPWHPSHUDWXUHLVORZHUWKDQ)
HI5RRPWHPSHUDWXUHLVKLJKHUWKDQ)
FP/RZWHPSHUDWXUHSURWHFWLRQ
NOTE:$OOWKHLOOXVWUDWLRQVLQWKLVPDQXDODUHIRU
H[SODQDWLRQSXUSRVHVRQO\<RXUDLUFRQGLWLRQHUPD\EH
slightly different.
NOTE: This air conditioner is designed to be operated
under the conditions listed above.
NOTE:3HUIRUPDQFHPD\EHUHGXFHGLIRXWVLGHWKHVH
operating temperatures.
USING THE AIR CONDITIONER
Controls
Air Conditioner Controls
&RROLQJ2SHUDWLRQ
2XWGRRU7HPS °F
,QGRRU7HPS °F
+HDWLQJ2SHUDWLRQ
2XWGRRU7HPS °F
,QGRRU7HPS °F