49-5000684 Rev. 1
Controls
USING THE AIR CONDITIONER
NOTE: :KHQWKHXQLWLVFRQWUROOHGE\DUHPRWHZDOO
WKHUPRVWDWVHHSDJHVDQGWKHXQLWZLOOGLVSOD\³/&´
The optional accessory included with the unit stating the
XQLWLV³&RQWUROOHGE\:DOO0RXQWHG7KHUPRVWDW´FDQEH
installed at the controls to inform the guest.
NOTE:)RUVRPHIXQFWLRQVWKHUHLVDVHFRQGGHOD\
after pressing a button.
NOTE: :KHQWKHUHDUHGLIIHUHQFHVUHJDUGLQJWKHXQLW
function between the Owner’s Manual and Remote
Thermostat the description in the Owner’s Manual shall
prevail.
Remote Thermostat Accessory
Controlled by Wall Mounted Thermostat
C
F
Features
This unit has many features. The servicer must be
familiar with these features in order to properly service
the unit.
Compressor Restart Delay
7KLVIHDWXUHH[WHQGVWKHRYHUDOOOLIHRIFRPSUHVVRUE\
SUHYHQWLQJWKHVKRUWF\FOLQJRIWKHDLUFRQGLWLRQHU:KHQ
the compressor starts, the unit is designed to run a
PLQLPXPRIPLQXWHV7KHFRPSUHVVRUZLOOWKHQEHRII
IRUDPLQLPXPRIPLQXWHVWRHTXDOL]HWKHUHIULJHUDQW
pressure before restarting.
Memory
The unit has a memory. If power is lost, all of the control
settings (mode, fan speed, on/off and configuration) are
UHPHPEHUHG:KHQSRZHULVUHVWRUHGDIWHUDSRZHU
failure, the unit will start in the mode (and configuration)
it was in when power was lost.
Automatic Evaporator Freeze Protection
$VHQVRURQWKHLQGRRUFRLOPRQLWRUVWKHFRLOWHPSHUDWXUH
and will turn the compressor off until the coil warms up.
The indoor fan will continue to run.
Automatic Quick Warm-up
(for heat pump models only)
If the room temperature falls to 8°F below the set point
temperature, the reverse cycle heat is shut off and the
electric strip heat is turned on for one cycle, until room
temperature is satisfied.
LED Indicators and Buttons
7KHXQLWKDV/('VWKDWFRUUHVSRQGWRWKHPRGHIDQ
VSHHGSRZHUDQGVHWSRLQWRSHUDWLRQWRLQGLFDWHWKHXQLW¶V
VWDWXV/('VIRU+,*+0('DQG/2:LQGLFDWHWKHIDQ
VSHHGWKDWLVVHOHFWHG/('VIRU)$1&22/DQG+($7
LQGLFDWHZKDWRSHUDWLQJPRGHLVDFWLYH/('IRU32:(5
LVWKHXQLW212))VWDWXV/(',IWKHXQLWLVLQ21PRGH
WKH/('ZLOOEHJUHHQ,IWKHXQLWLV2))WKH/('ZLOOEH
off.
High Temperature Protection in Heating Operation
The compressor and(or) electric heater will be switched
off to prevent damage in high indoor air temperatures or
when there is a defective indoor temperature sensor.