21 of 36
Indesit Company
Service Manual UK English
POWER/CONTROL MODULE Parameters
(Values stated are for guidance only - may change without notice)
DEFROST AND DRIP TRAY HEATING ELEMENTS
FREEZER FAN OPERATION
FRIDGE LAMP OPERATION
continued…
Defrost and Drip Tray Heating
Elements -
The parameters utilised to start the
defrost cycle are as follows:
• Compressor ON time since the last defrost cycle.
600 minutes
• Duration of doors open condition.
If the door is opened more than 30 minutes, there is a
defrost every 2 hours.
• Enabling Super Freeze.
The defrost cycle is initiated as soon as you start up the
super freeze function. While the super freeze function is
enabled there will be a defrost cycle every 2 hours.
The parameters utilised to end the
defrost cycle are as follows:
• Maximum time defrost heater is ON.
32 minutes
Defrost end temperature (freezer evaporator sensor).
+10°C
Freezer Fan Operation -
The freezer fan is managed by the
power module and is switched on/off
after a preset time interval that is
parameterised in the module
memory after a compressor start/
stop.
The defrost procedure is preceded by activation of the fan
and the fridge damper opening for a timed interval that
is parameterised in the module memory.
4 minutes
After the defrost cycle the fan starts after a timed interval
following a compressor start, also this interval is
parameterised in the module memory;
12 minutes PLUS 5 minutes
NOTE: This interval is different from the interval
programmed for normal operating conditions.
Fridge Lamp Operation -
A reed switch and a triac on the
power module control the Interior
lamps.
If the door remains open for a timed period that is greater
than the time interval stored in the module memory, the
lamp will start flashing and continue until the door is
closed.