EasyManua.ls Logo

Hotsy 797SS - Page 15

Hotsy 797SS
32 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Manual Hotsy, 700 Series • 9.808-301.0
15
PRESSURE WASHER
OPERATOR’S MANUAL
MAINTENANCE
If pressure from pump or thermal expansion should ex-
ceed safe limits, the relief valve will open, allowing high
pressure to be discharged through hose to ground.
Cau-
tion: Inspect relief valve annually for any obstruction
.
Unloader Valve
WARNING: The unloader valve on this pressure
washer has been factory set and sealed and is a eld
nonadjustable part. Tampering with the factory setting
may cause personal injury and/or property damage,
and will void the manufacturer warranty. For replace-
ment refer to Pump Assembly.
AVERTISSEMENT : La soupape de décharge sur
cette laveuse à pression a été réglée en usine, puis
scellée, et est une pièce non réglable. L'altération
du paramètre de l'usine pourrait causer des lésions
corporelles et/ou des dommages à la propriété, et
annulera la garantie du fabricant.
ADVERTENCIA: La válvula de descarga de esta
hidrolavadora se ha ajustado y sellado en fábrica y
es una pieza no ajustable en el campo. La alteración
del ajuste de fábrica puede causar lesiones perso-
nales y/o daños materiales y anula la garantía del
fabricante.
Burner Fuel Filter
Drain any water which has accumulated in fuel lter and
clean or replace element as needed. For replacement
parts, refer to Burner Assembly.
Heating Coil
Coil Descaling: In hard water areas, scale buildup within
the heating coil will occur. Scale deposits will decrease
the water temperature rise and may eventually clog the
heating coil. Contact your local service center when
descaling is needed.
Coil Desooting: Poor grades of fuel oil or inadequate
combustion air will cause heavy soot buildup on the
outside surface of the heating coil. These deposits will
insulate the coil. This will restrict the air ow through the
coil, further aggravating the soot buildup. Contact your
local service center when desooting is needed.