Table 19 CLI Monitoring Commands (continued)
Usage
1
Command
Returns the report settings for each E-mail address configured for notification alerts.getEmail
Deletes the specified E-mail address from the E-mail notification alert settings. Where the
options are:
-a <s> - E-mail address (required)
deleteEmail
-c <s> - VLS node IP address (required)
-f - Force. This parameter is ignored and is present only for backward compatibility
(optional)
-y <n> - Email type (1-long with attachment, 2-long, 4-short, 8-reports, 16-configuration)
(required)
-h - Displays command usage information (optional)
Specifies an SNMP management console to receive SNMP traps from the VLS. Where
the options are:
-a <s> - SNMP server IP address (required)
addSnmpServer
-c <s> - VLS node IP address (required)
-m <s> - Community (Public, ...) (required)
-v <s> - Trap version (required)
-s <n> - Severity (1-Error, 2-Warning, 4-Info, or 8-Unknown) (required)
-h - Displays command usage information (optional)
Returns the SNMP management console configuration settings for notification alerts.getSnmp
Deletes the specified SNMP management console from the SNMP notification alert
settings. Where the options are:
-a <s> - SNMP server IP address (required)
deleteSnmpServer
-c <s> - VLS node IP address (required)
-f - Force. This parameter is ignored and is present only for backward compatibility
(optional)
-h - Displays command usage information (optional)
1 <s> = string; <n> = number; <f> = filename
VLS Commands 145