EasyManuals Logo

HP 3PAR StoreServ 7400 2-node Administrator's Manual

HP 3PAR StoreServ 7400 2-node
204 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #76 background imageLoading...
Page #76 background image
In the showport command output shown below, primary port 0:0:1 corresponds to partner
persistent port 1:0:1 with a failover of state of none.
root@snodeb40:S170# showport
N:S:P Mode State ----Node_WWN---- -Port_WWN/HW_Addr- Type Protocol Label
Partner FailoverState
0:0:1 target ready 2FF70002AC0000AA 20010002AC0000AA host FC -
1:0:1 none
0:0:2 initiator ready 2FF70002AC0000AA 20020002AC0000AA disk FC -
- -
0:0:3 target loss_sync 2FF70002AC0000AA 20030002AC0000AA free FC -
1:0:3 none
0:0:4 target ready 2FF70002AC0000AA 20040002AC0000AA host FC -
- -
0:3:1 target loss_sync 2FF70002AC0000AA 20310002AC0000AA free FC -
1:3:1 none
0:3:2 initiator ready 2FF70002AC0000AA 20320002AC0000AA disk FC -
- -
0:5:1 initiator ready 2FF70002AC0000AA 20510002AC0000AA disk FC -
- -
0:5:2 target ready 2FF70002AC0000AA 20520002AC0000AA host FC -
1:5:2 none
0:6:1 peer offline - 0002AC53069C rcip IP RCIP0
- -
1:0:1 target ready 2FF70002AC0000AA 21010002AC0000AA host FC -
0:0:1 none
1:0:2 initiator ready 2FF70002AC0000AA 21020002AC0000AA disk FC -
- -
1:0:3 target loss_sync 2FF70002AC0000AA 21030002AC0000AA free FC -
0:0:3 none
1:0:4 initiator ready 2FF70002AC0000AA 21040002AC0000AA host FC -
- -
1:3:1 target loss_sync 2FF70002AC0000AA 21310002AC0000AA free FC -
0:3:1 none
1:3:2 initiator loss_sync 2FF70002AC0000AA 21320002AC0000AA free FC -
- -
1:5:1 initiator ready 2FF70002AC0000AA 21510002AC0000AA disk FC -
- -
1:5:2 target ready 2FF70002AC0000AA 21520002AC0000AA host FC -
0:5:2 none
1:6:1 peer offline - 0002AC520041 rcip IP RCIP1
- -
In the following example, port 0:0:1 is in the process of failing over to port 1:0:1.
root@snodeb40:S170# showport 0:0:1 1:0:1
N:S:P Mode State ----Node_WWN---- -Port_WWN/HW_Addr- Type Protocol Label Partner
FailoverState
0:0:1 target offline 2FF70002AC0000AA 20010002AC0000AA free FC - 1:0:1
failover_pending
1:0:1 target ready 2FF70002AC0000AA 21010002AC0000AA host FC - 0:0:1
none
In this example, the failover from port 0:0:1 to port 1:0:1 has completed.
root@snodeb40:S170# showport 0:0:1 1:0:1
N:S:P Mode State ----Node_WWN---- -Port_WWN/HW_Addr- Type Protocol Label Partner
FailoverState
0:0:1 target offline 2FF70002AC0000AA 20010002AC0000AA free FC - 1:0:1
failed_over
76 Managing Ports and Hosts

Table of Contents

Other manuals for HP 3PAR StoreServ 7400 2-node

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP 3PAR StoreServ 7400 2-node and is the answer not in the manual?

HP 3PAR StoreServ 7400 2-node Specifications

General IconGeneral
Node Count2
CategoryStorage
Maximum Raw Capacity1.2 PB
Storage Capacity1.2 PB
Operating SystemHP 3PAR OS
Power SupplyRedundant Power Supplies
ModelStoreServ 7400
Drive Types SupportedSSD, SAS
Drive TypesSSD, SAS
Host Interfaces16 Gb Fibre Channel, 10 Gb iSCSI
Host ConnectivityFibre Channel, iSCSI
Host Interface16 Gb Fibre Channel, 10 Gb iSCSI
RAID LevelsRAID 1, RAID 5, RAID 6
RAID Level0, 1, 5, 6
Management InterfaceCLI
Memory64 GB
Cache Memory64 GB
Data ServicesThin Provisioning, Deduplication, Compression, Snapshots, Replication
Form FactorRack-mounted
Installed Devices / Modules Qty2
Storage Controller TypeActive/Active

Related product manuals