HP Enterprise Virtual Array Updating Product
Software Guide (XCS 10000000)
Abstract
This guide describes how to upgrade controller software, disk drive firmware, and related EVA management software on the
HP EVA4400 and HP EVA6400/8400. HP P6300/P6500 EVAs are not included in this document because they are already
running XCS 10000000 and do not need an upgrade. P6000, used throughout this document, is the new branding for the
Enterprise Virtual Array product family. General references to HP P6000 Command View may also refer to earlier versions of
HP Command View EVA.
This guide is intended for field personnel and customers who are experienced with these array models, storage area networks,
HP P6000 Command View and associated software. This guide does not provide information about upgrading or replacing
array hardware.
The information in this guide is subject to change. Please check for the latest version before starting an upgrade.
HP Part Number: 667991-001
Published: June 2011
Edition: 2

Table of Contents

Other manuals for HP 4400

Questions and Answers

  • N
    Nancy WestSep 3, 2025
    What to do if the disk cannot be code loaded because disk is part of a RAID0 group on HP Server?
    • K
      Kayla MooreSep 4, 2025
      If the disk cannot be code loaded because disk is part of a RAID0 group on your HP Server, remove disks that contain RAID0 (Vraid0) data from the group and restart the disk drive firmware upgrade.
  • B
    bmacdonaldSep 2, 2025
    What to do if unable to determine the condition of the volume on HP Server?
    • T
      Tammy MckeeSep 2, 2025
      If the condition of the volume cannot be determined during a drive code load on your HP Server, check the drive properties in HP P6000 Command View for problems. Resolve any issues and restart the disk drive firmware upgrade.
  • P
    pamelamosesAug 31, 2025
    What to do if disk group has background reconstructing in progress on HP Server?
    • L
      Linda ArcherAug 31, 2025
      If the disk group containing the physical store has background reconstructing or reverting in progress on your HP Server, reduce the I/O using the I/O analysis for the online disk drive firmware upgrade, and then restart the upgrade.
  • E
    emunozAug 29, 2025
    What to do if disk cannot be code loaded because it is part of a group on HP Server?
    • P
      Peter YoungAug 29, 2025
      If the disk cannot be code loaded because it is part of a group on your HP Server, restart the disk drive firmware upgrade.
  • R
    Richard JohnsonAug 28, 2025
    What to do if drive code load fails to write firmware to drive buffer on HP Server?
    • T
      Tiffany HarrisonAug 28, 2025
      If the drive code load fails to write firmware to the drive buffer on your HP Server, check the drive properties in HP P6000 Command View for problems. Resolve any identified issues, and then restart the disk drive firmware upgrade.
  • J
    jason52Aug 27, 2025
    How to fix 'View is not set or view list is null' error on HP Server?
    • D
      dmurrayAug 27, 2025
      If the HP P6000 Command View cannot build the view of the array, click OK, wait one to five minutes, and retry the command. If you still cannot see the array, stop and restart HP P6000 Command View.
  • M
    melissaandersonAug 22, 2025
    Why does my HP Server show an unknown storage system?
    • A
      Andre SpenceAug 22, 2025
      If your HP P6000 Command View reports an unknown storage system, it might be due to a communication loss with the controllers. If the array has a heavy I/O load, the HBA in the management server may time out commands to the controllers, making the array appear in an unknown state. This usually corrects itself within a minute. Alternatively, you can perform a Rediscover operation to initiate new commands to the controller. Also, ensure you're using an HP P6000 Command View version compatible with XCS 10000000. If not, upgrade HP P6000 Command View to a compatible version.

Summary

Getting Started with HP Enterprise Virtual Array Updates

Upgrade Overview

Explains online and offline upgrade methodologies.

Upgrade Paths

Details supported upgrade and downgrade routes.

Preparing for the Upgrade Process

Checking Array Hardware

Assesses the physical health of array components.

Checking and Upgrading SAN Infrastructure

Validates network and host connectivity.

Evaluating Your Configuration

Assesses system readiness based on gathered data.

Managing Host I;O Timeouts

Adjusts system timeouts for smooth online upgrades.

Backing Up All Array Data

Recommends a full data backup before the upgrade.

Saving Array Configuration Data

Collects and stores current array settings.

Upgrading the Enterprise Virtual Array

Checking the Health of the Enterprise Virtual Array

Final check of array components' operational status.

Disabling Array Passwords

Removes password protection to facilitate the upgrade.

Halting All Host Access for Offline Upgrade

Stops host I/O for offline procedures.

Upgrading the Controller Software

The core process of updating the array's firmware.

Upgrading Disk Drive Firmware

Updates firmware on individual storage drives.

Resuming Array Operation

Returns the array to normal service post-upgrade.

Troubleshooting HP Enterprise Virtual Array Issues

HP P6000 Command View Errors

Details specific error messages and their causes.

HTTP Status 404, 503 Errors

Addresses web server communication failures.

Unknown Storage System

Resolves issues where the array is not recognized.

Disk Drive Firmware Upgrade Errors

Handles issues during disk firmware updates.

Support and Other Resources

HP Technical Support

Provides contact information for assistance.

Related Information

Links to additional documents and websites.

HP 4400 Specifications

General IconGeneral
BrandHP
Model4400
CategoryController
LanguageEnglish

Related product manuals