493
Chapter 8, Programming The Call Processing Subsystem
Programming The CALL CONTROL Screen
DSAT/DST (hex)
The DSAT/DST field is displayed only when the System Type field is set to
NAMPS and the Display field is set to NMeas.
The DSAT/DST field displays the received
DSAT/DST sequence from the mobile
station on the reverse voice channel. The received sequence is displayed in
hexadecimal and can be checked against the DSAT value displayed in the DSAT
right-hand DSAT field. Four dashes (----) indicate no carrier is present to
measure. A numeric value would only be displayed when the Test Set’s
Connected annunciator is lit (connected state).
The :DSAT:MEASurement? query command is used to query the contents of the
left-hand subfield.
There is no command form of the :MEASurement? query.
Syntax
:DSAT:MEASurement?
Example
OUTPUT 714;"CALLP:NAMP:DSAT:MEASurement?"
ENTER 714;MEASured_dsat$
ESN (dec):
This information string contains the electronic serial number (ESN), in decimal
form, received from the mobile station on the reverse control channel in response
to a forward control channel message.
The
ESN (dec): field is only displayed when the Display field is set to Data
and a reverse control channel message containing this information has been
decoded.
Refer to the
Display field description, on page 483, for information on how to
read data displayed in the upper right hand portion of the CALL CONTROL screen.