62 Chapter 2 System Error Codes
System Error Codes
Problem Description:
Aerosol Fan not connected.
Corrective Action:
Try the following:
• Check that the Aerosol Fan cable is not damaged and is correctly connected to the Interconnect
PCA.
• Replace the Aerosol Fan ⇒ Page 300.
System Error:
46:03
Problem Description:
Primer servo shutdown.
Corrective Action:
Try the following:
• Switch the Power OFF from the back of the Printer and disconnect the Power cord. Reconnect the
power cord and power On the Printer.
• Replace the Primer Assembly ⇒ Page 294.
• Replace the PrintMech PCA ⇒ Page 384.
• Replace the Interconnect PCA ⇒ Page 357.
System Error:
46:10
Problem Description:
Electrical fault in primer motor.
Corrective Action:
Try the following:
• Switch the Power OFF from the back of the Printer and disconnect the Power cord. Reconnect the
power cord and power On the Printer.
• Replace the Primer Assembly ⇒ Page 294.
• Replace the PrintMech PCA ⇒ Page 384.
• Replace the Interconnect PCA ⇒ Page 357
System Error:
46:13
Problem Description:
Primer test distance failed.
Corrective Action:
Try the following:
• Check that the Primer Arm is not damaged and there are no obstacles in its way.