Continuable and Non-Continuable Error Codes 65
System Error Codes
• Switch the Power OFF from the back of the Printer and disconnect the Power cord. Reconnect the 
power cord and power On the Printer.
• Check that the Printer has the latest Firmware version. If not, update the Firmware to the latest 
version.
• Check that the OMAS Module cable is not damaged and is correctly connected to the OMAS 
Controller PCA.
• Replace the OMAS Controller Card ⇒ Page 362
• Replace the OMAS Module ⇒ Page 351.
System Error:
50.2:10
Problem Description:
Error with the media advance sensor controller board.
Corrective Action:
Try the following:
• Switch the Power OFF from the back of the Printer and disconnect the Power cord. Reconnect the 
power cord and power On the Printer.
• Check that the Printer has the latest Firmware version. If not, update the Firmware to the latest 
version.
• Check that the CAN cable and the Encoder Cable are correctly connected to the OMAS PCA and 
the Main PCA (refer to 
• Check the connection between the OMAS PCA and the Sausalito PCA (the Sausalito is the card 
connected just behind the OMAS PCA).
• Check that the OMAS Module cable is not damaged and is correctly connected to the OMAS 
Controller PCA.
• Replace the OMAS Controller Card ⇒ Page 362
System Error:
51:10
Problem Description:
Error detected with the sensor on the Window.
Corrective Action:
Try the following:
• Check that the Window Sensor cable is not damaged and is correctly connected to the Interconnect 
PCA.
• Replace the Window Sensor.
System Error:
51.1:10
Problem Description:
Error detected with the sensor on the Service Station Door.