2. Position the OMAS under the printer and connect the large ribbon.
3. Lock the clips of the large ribbon cable connector.
4. Carefully push the OMAS fully up into its mounting so that the OMAS window protrudes slightly
ABOVE the Print Platen (approximately 0-2 mm). To ensure the OMAS is correctly positions, slide
a sheet of paper over the Platen Ribs until it is stopped by the OMAS. This ensures the OMAS is
protruding slightly above the platen.
CAUTION: Make sure the OMAS is pushed completely up into its mounting or you will
encounter an error during the OMAS calibration because it will not be able to focus on the paper.
ENWW