If the system error persists, replace the ESP
Embedded SpectroPhotometer (ESP) on page 355.
●
Perform an ESP basic test (CLC), to ensure that the replaced part is working correctly.
SE 58.1:10
Cause: Embedded PhotoSpectrometer (ESP) Shutter Actuator failure
Solution: Try the following:
●
Replace the ESP Shutter Actuator Assembly.
●
Perform the ESP Shutter Diagnostic Test to ensure that there is no other problem preventing shutter
operation.
●
Perform am ESP basic test (CLC) to ensure that the replaced part is working correctly.
SE 58.2:10
Cause: Embedded PhotoSpectrometer (ESP) Shutter Deactivator failure
Solution: Try the following:
●
Check that the Shutter Deactivator is correctly screwed into place.
●
Replace the Left Spittoon Assembly (which contains the Shutter Deactivator).
●
Perform the ESP Shutter Diagnostic Test to ensure that there is no other problem preventing shutter
operation.
●
Perform a ESP basic test (CLC) to ensure that the replaced part is working correctly.
SE 59.1:09
Cause: Two electrical parts have been replaced at the same time
Solution: Replace one part at a time, and restart the printer before replacing another.
SE 59.2:00
Cause: An unsupported or reused part has been installed
Solution: Install only new parts recommended by HP for this printer.
SE 60.1:11
Cause: Initialization error
Solution: Try the following:
●
Turn the power off at the rear of the printer and disconnect the power cord.
●
Check that the printer is properly connected in all other respects. In particular, check that the tag
cable is well connected to the ISS Top PCA, and the ISS Top PCA is well connected to the
PrintMech PCA.
64 Chapter 2 System error codes ENWW
System error codes