SE 94:02
Cause: Color calibration error: some of the consistency checks on the Embedded SpectroPhotometer
(ESP) measurements failed, which could have several causes
Solution: Try the following:
●
Ensure that the paper type selected corresponded to the paper actually loaded.
●
Inspect the CLC printed target to detect any printing defect: banding, missing colors, etc. If an
issue is detected, run the Printing IQ Full Calibration procedure to fix any printing problems.
●
Check that color calibration is supported for this paper type: translucent, plain and heavily colored
papers cannot be color-calibrated.
●
If the problem persists, try calibrating an HP coated paper (if available). If this calibration fails,
replace the ESP.
SE 94:10
Cause: Embedded SpectroPhotometer (ESP) contaminated by aerosol
Solution: Try the following:
●
Replace the ESP
Embedded SpectroPhotometer (ESP) on page 355.
●
Perform the ESP basic test (CLC) to ensure that the replaced part is working correctly.
ENWW
Continuable and non-continuable error codes
71
System error codes