Control panel message Description Recommended action
3. Back up contents and replace hard drive.
302-Hard Disk 2: SMART Hard Drive Detects
Imminent Failure
Hard drive is about to fail. (Some hard drives
have a hard drive rmware patch that will x an
erroneous error message.)
1. Determine if hard drive is giving correct
error message. Run the Drive Protection
System test under using F2 Diagnostics
when booting the computer.
2. Apply hard drive rmware patch
if applicable. (Available at
http://www.hp.com/support.)
3. Back up contents and replace hard drive.
309 – 30C: Hard Disk 3–6: SMART Hard Drive
Detects Imminent Failure
Hard drive is about to fail. (Some hard drives
have a hard drive rmware patch that will x an
erroneous error message.)
1. Determine if hard drive is giving correct
error message. Run the Drive Protection
System test under using F2 Diagnostics
when booting the computer.
2. Apply hard drive rmware patch
if applicable. (Available at
http://www.hp.com/support.)
3. Back up contents and replace hard drive.
3F0–Boot Device Not Found Boot device not found. Insert boot device or load operating system.
3F1–Hard Disk 1 Error Hard disk 1 error. 1. Check and/or replace cables.
2. Clear CMOS. (See Password security and
resetting CMOS on page 156.)
3. Replace the hard disk drive.
3F2–Hard Disk 2 Error Hard disk 2 error. 1. Check and/or replace cables.
2. Clear CMOS. (See Password security and
resetting CMOS on page 156.)
3. Replace the hard disk drive.
400-Serial Port A Address Conict Detected Both external and internal serial ports are
assigned to the same resources.
1. Remove any serial port expansion cards.
2. Clear CMOS. (See Password security and
resetting CMOS on page 156.)
3. Recongure card resources and/or run
Computer Setup or Windows utilities.
401-Serial Port B Address Conict Detected Both external and internal serial ports are
assigned to the same resources.
1. Remove any serial port expansion cards.
2. Clear CMOS. (See Password security and
resetting CMOS on page 156.)
3. Recongure card resources and/or run
Computer Setup or Windows utilities.
402-Serial Port C Address Conict Detected Both external and internal serial ports are
assigned to the same resources.
1. Remove any serial port expansion cards.
2. Clear CMOS. (See Password security and
resetting CMOS on page 156.)
3. Recongure card resources and/or run
Computer Setup or Windows utilities.
403-Serial Port D Address Conict Detected Both external and internal serial ports are
assigned to the same resources.
1. Remove any serial port expansion cards.
2. Clear CMOS. (See Password security and
resetting CMOS on page 156.)
152 Chapter 9 POST error messages and diagnostic front panel LEDs and audible codes

Table of Contents

Other manuals for HP EliteOne 705 G2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP EliteOne 705 G2 and is the answer not in the manual?

HP EliteOne 705 G2 Specifications

General IconGeneral
BrandHP
ModelEliteOne 705 G2
CategoryDesktop
LanguageEnglish

Related product manuals