8.0 Solid state disk (SSD) support
Array family
1
Minimum/maximum
number of drives
Vraid level
HP P6000
Business Copy
HP P6000 Continuous
Access
HP P6000
DC-Management
EVA4400,
EVA6400/8400
6/8
Vraid1
2
, Vraid5
All features supported Not supported
Extend/shrink not
supported
This table lists feature support for solid state disks. SSDs must be in a separate disk group. For disk drive firmware versions and other general disk drive
and XCS support, see the HP P6000 Enterprise Virtual Array Disk Drive Firmware Support document, which is available at:
http://www.hp.com/support/manuals
. Under storage, select Disk Storage Systems, and then select your array model under P6000/EVA Disk
Arrays.
1
The 72 GB SSD requires XCS 09500000 or later. The 200 GB and 400 GB SSDs require XCS 09534000 or later.
2
Vraid1 requires XCS 09534000 or later.
39

Other manuals for HP EVA P6000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP EVA P6000 and is the answer not in the manual?

HP EVA P6000 Specifications

General IconGeneral
ModelHP EVA P6000
Number of Storage Controllers2
Management SoftwareHP Command View EVA
Drive TypesSAS, SSD
RAID LevelsRAID 0, 1, 5, 6
Connectivity8 Gb Fibre Channel, 10 Gb iSCSI, 1 Gb iSCSI
Form FactorRack-mounted
Storage Controller TypeDual controllers