The OA CLI SHOW CAE command can identify specific VRDs associated with these faults. See Core
Analysis Engine on page 79 for more information.
The SubFRU deconfiguration display section has the same layout as the SubFru Isolation display.
CPU socket subcomponent displays
There are three different sets of CPU subcomponent data, contained in three different displays.
CPU core
- SubFru Isolation -
- Processor Module: Intel Xeon (R) E7-8800 processor
-
- Core 0 -
FLD FLI MLD MLI LL
Cache: 0 0 0 0 0
TLB: 0 0 0 0 .
• FL indicates ‘First Level’ and corresponds to the L1 cache.
• ML indicates ‘Mid Level’ and corresponds to the L2 cache.
• LL indicates ‘Last Level’ and corresponds to the L3 cache.
• I indicates ‘Instruction.’ For example, the FLI cache is the First Level Instruction cache.
• D indicates ‘Data.’ For example, the MLD cache is the Mid Level Data cache.
VRMs supported by this display are as follows:
• FP_regs
• GP_regs
• other (an unspecified fault has been identified within the processor core)
CPU memory
- SubFru Isolation -
- Processor Module: Intel Xeon (R) E7-8800 processor -
- Memory –
-0- -1-
Mbox: 0 0
CPU Uncore
- SubFru Isolation -
- Processor Module: Intel Xeon (R) E7-8800 processor -
- Uncore -
-0- -1- -2-
R-QPI: 0 0 0
UBOX/PMU: 0 . .
CPU integrated I/O ports
- SubFru Isolation -
- Processor Module: Intel Xeon (R) E7-8800 processor -
- IIO -
Root Port ID 0x0 (DMI): 0
Root Port ID 0x3 (2A): 0
Root Port ID 0x5 (2C): 0
Root Port ID 0x7 (3A): 0
Root Port ID 0x9 (3C): 0
IIO: Fault
The last line is printed only when an I/O error occurs that is unrelated to any port.
CPU socket subcomponent displays 71