DHCP: Disabled
IP Address: 10.67.52.ccc
Netmask: 255.255.254.0
Gateway Address: 10.67.52.aaa
Primary DNS: 0.0.0.0
Secondary DNS: 0.0.0.0
MAC Address: 9C:8E:99:29:xy:xy
Link Settings: Auto-Negotiation, 1000 Mbit, Full Duplex
Link Status: Active
Enclosure IP Mode: Disabled
Troubleshooting fabric issues
Cause
The Integrity Superdome X has fabric connections between all the blades installed in the compute
enclosure.
Test fabric
To determine the healthy status for all crossbar connections, use the HR> test fabric command. This
is a valuable test during installation when all partitions can be taken down at the same time. During
normal operation when some or all partitions can’t be taken down at the same time, use the procedure
described in Show complex status below.
IMPORTANT:
The HR> test fabric requires a complex outage. Before running HR> test fabric, all
indicted and deconfigured parts must be cleared and the partition must be powered off.
NOTE:
Test fabric includes both test camnet and test clocks.
OA1 HR> test fabric
Begin test 1: System Fabric Components
Acquitting any current fabric and CAMNet indictments, and deconfigurations.
Beginning fabric test
SUCCESS: System Fabric test complete
System Fabric routed successfully.
Begin test 2: Management Network Components
CAMNet test has executed without finding faults
Management connectivity test complete
Begin test 3: Global Clock Components
Clocks test started...
Blade Sys Clk 0 Sys Clk 1
========== ========== ==========
Blade 1/1 OK OK
Blade 1/2 OK OK
Blade 1/3 OK OK
Blade 1/4 OK OK
Blade 1/5 OK OK
Blade 1/6 OK OK
Blade 1/7 OK OK
Blade 1/8 OK OK
94 Troubleshooting fabric issues