Field Description 
Critical Event  Indicates whether a critical error is present: 0 for no and 1 for yes 
Local Evaluating 
Indicates whether the local-to-remote configuration negotiation is 
complete:  
•  COMPLETE for completed 
•  REVERSED for uncompleted 
Remote Evaluating 
Indicates whether the remote-to-local configuration negotiation is 
complete: 
•  COMPLETE for completed 
•  REVERSED for uncompleted 
Packets statistic  Statistics about Ethernet OAMPDUs sent and received 
OAMPDU  Total number of the Ethernet OAMPDUs sent and received 
OAMInformation  Number of the Information OAMPDUs sent and received 
OAMEventNotification  Number of the Event notification OAMPDUs sent and received 
OAMUniqueEventNotification 
Number of the unduplicated Event notification OAMPDUs sent or received 
uniquely 
OAMDuplicateEventNotification  Number of the duplicate Event notification OAMPDUs sent or received 
 
# Display the Ethernet OAM information of the peer port Ethernet 1/0/1. 
<Sysname> display oam remote interface ethernet 1/0/1 
Port        : Ethernet1/0/1 
Link Status : Up 
Information of the latest received OAM packet: 
OAMRemoteMACAddress       : 00e0-fd73-6502 
OAMRemotePDUConfiguration : 1500 
 
OAMRemoteState : 
-------------------------------------------------------------------------- 
Remote_mux_action         : FWD         Remote_par_action      : FWD 
 
OAMRemoteConfiguration : 
-------------------------------------------------------------------------- 
OAM Mode                  : Active      Unidirectional Support : YES 
Loopback Support          : YES         Link Events            : YES 
Variable Retrieval        : NO 
 
OAMRemoteFlagsField : 
-------------------------------------------------------------------------- 
Link Fault                : 0           Dying Gasp             : 0 
Critical Event            : 0           Local Evaluating       : COMPLETE 
Remote Evaluating         : COMPLETE 
Table 2 Output description 
Field Description 
Port Port index 
3