Parameters 
|: Filters command output by specifying a regular expression. For more information about regular 
expressions, see the Fundamentals Configuration Guide. 
begin: Displays the first line that matches the specified regular expression and all lines that follow. 
exclude: Displays all lines that do not match the specified regular expression. 
include: Displays all lines that match the specified regular expression. 
regular-expression: Specifies a regular expression, a case-sensitive string of 1 to 256 characters. 
Description 
Use the display oam configuration command to display global Ethernet OAM configuration, including 
the periods and thresholds for Ethernet OAM link error event detection.  
Related commands: oam errored-symbol period, oam errored-symbol threshold, oam errored-frame 
period, oam errored-frame threshold, oam errored-frame-period period, oam errored-frame-period 
threshold, oam errored-frame-seconds period, oam errored-frame-seconds threshold, oam timer hello, 
and oam timer keepalive. 
Examples 
# Display global Ethernet OAM configuration.  
<Sysname> display oam configuration 
Configuration of the link event window/threshold : 
-------------------------------------------------------------------------- 
Errored-symbol Event period(in seconds)           :     1 
Errored-symbol Event threshold                    :     1 
Errored-frame Event period(in seconds)            :     1 
Errored-frame Event threshold                     :     1 
Errored-frame-period Event period(in ms)          :     1000 
Errored-frame-period Event threshold              :     1 
Errored-frame-seconds Event period(in seconds)    :     60 
Errored-frame-seconds Event threshold             :     1 
 
Configuration of the timer : 
-------------------------------------------------------------------------- 
Hello timer(in ms)                                :     1000 
Keepalive timer(in ms)                            :     5000 
Table 3 Output description 
Field Description 
Configuration of the link event 
window/threshold 
Detection intervals and triggering thresholds configured for link events 
Errored-symbol Event period (in 
seconds) 
Errored symbol event detection interval, which defaults to one second. 
Errored-symbol Event threshold  Errored symbol event triggering threshold, which defaults to 1. 
Errored-frame Event period (in 
seconds) 
Errored frame event detection interval, which defaults to one second. 
Errored-frame Event threshold  Errored frame event triggering threshold, which defaults to 1. 