2. Remove four screws (callout 1), the scanner cover (callout 2) and the sheet-metal plate (callout 3).
NOTE: The scanner cover and plate can be removed as one assembly.
Figure 1-107 Remove the laser/scanner assembly (2 of 7)
2
3
1
3. Release two tabs (callout 1), and then slightly separate the motor driver PCA (callout 2) from the
product.
CAUTION: The motor driver PCA is still connected to the product by the wire harnesses and a
FFC.
Figure 1-108 Remove the main motor (3 of 7)
2
1
ENWW Main assemblies 75