Power-on checks
When you turn on the product, if it does not make any sound or if the control-panel display is blank,
check the following items:
Verify that the product is plugged directly into an active electrical outlet that has the correct
voltage. Do not plug the product into a surge protector or power strip.
Press the power button.
Verify that the formatter is seated and operating correctly.
Remove any HP Jetdirect accessories or other devices, and then try to turn the product on again.
Ensure that the control-panel display is connected.
Check the two fuses on the power supply.
If necessary, replace the power supply.
If necessary, replace the DC controller.