Commands and Responses
HP NonStop TMF Management Programming Manual540140-008
5-104
INFO AUDITTRAIL
ZCommitHoldTimer
specifies the maximum time to stay in activated commit-hold mode, in seconds.
This field contains a nonzero value only for the MAT; for auxiliary audit trails it
is always NULL. Values can range from 5 to 86400. The value -1 specifies
infinite.
ZTimeoutAction
specifies the action to take when the commit-hold timer expires. The following
values are valid:
This field is returned only for the MAT, and is not valid if the ZCommitHoldTimer
value is -1.
Usage Guidelines
Any user can issue this command.
You can enter this command at any time, whether or not TMF has been started.
Multiple response records are allowed to enable the command to return all the
requested information.
ZTMF-VAL-ZLTCH-ActionSuspend Suspend commit-hold condition.
ZTMF-VAL-ZLTCH-ActionCrash Crash TMF.