will be recorded in the event logs: An unsupported cable or SFP was inserted". At the same time, the host port will not
show a status of "Down".
Workaround: Do the following:
1. Verify that the SFP+, Copper Cable, or Direct Attach Cable is a supported component. For support information, see the
P2000 G3 QuickSpecs on the P2000 G3 product page: http://www.hp.com/go/p2000.
2. If the components are indeed listed as supported models, remove and reinsert the SFP+, Copper Cable, or Direct Attach
cable.
3. If this does not correct the issue with the SFP+, Copper Cable, or Direct Attach Cable connected to the controller, either
remove and reinsert the controller or power down and reapply power to the array.
Issue: RHEL 5 Update 5 will not shutdown properly when using the iSCSI initiator utilities shipped in RHEL 5 Update 5 to
access the array.
Workaround: See issue 583218 on the Red Hat Bugzilla bug-tracking system https://bugzilla.redhat.com/show_bug.cgi?
id=583218 for the current status of the issue and possible workarounds.
Issue: When using explicit LUN mapping, using long IQN names for the iSCSI Initiator can cause the array to map the
LUN incorrectly. A predefined area is used to store explicit LUN mapping information per LUN and, with longer IQN
names, this area can be exhausted. This issue is not dependent on the number of paths to the LUN.
Workaround: Shorten the IQN name on the nodes.
The following formula is used to calculate the maximum IQN name length based on the number of hosts being explicitly
mapped to a LUN on the array:
Maximum IQN Character Length = (4083 / n) 7 (Where n = number of hosts nodes explicitly mapped to
a LUN on the array.)
NOTE: By specification, 223 is the maximum IQN length allowed.
The following table provides the calculated values based on the number of hosts being explicitly mapped to a LUN on the
array:
Number of hosts explicitly mapped
to a LUN and the Maximum IQN
character length
Number of hosts explicitly mapped
to a LUN and the Maximum IQN
character length
Number of hosts explicitly mapped
to a LUN and the Maximum IQN
character length
7649116332231–17
74501133421918
73511093520719
71521063619720
70531033718721
68541003817822
6755973917023
6556954016324
6457924115625
6358904215026
6259874314427
6160854413828
5961834513329
5862814612930
5763794712431
5664784812032
Issue: USB CLI becomes unusable after a Management Controller reboot in Windows environments.
14 Known issues and workarounds

Other manuals for HP P2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP P2000 and is the answer not in the manual?

HP P2000 Specifications

General IconGeneral
Drive SupportSAS
ControllerDual Controller options available
Host Interface6Gb SAS, 8Gb FC, 1Gb iSCSI
RAID LevelsRAID 0, 1, 5, 6, 10
Storage TypeSSD
Hot-swappable ComponentsDrives, controllers, power supplies, fans
Dimensions8.9 x 44.8 x 63.5 cm (3.5 x 17.6 x 25 inches)
Drive BaysUp to 12 LFF or 24 SFF drive bays per enclosure

Related product manuals