◦ If a partner controller is restarted during replication, settings in the Scheduler will now be
maintained; no extraneous replication images will be created.
◦ Replication schedules will no longer cause the SMU to time out and become unresponsive.
◦ Improved the messaging when attempting to detach a secondary replication volume and an
initial replication has not occurred.
◦ When creating replication sets, if network settings are configured incorrectly, the correct
error message will now be displayed.
◦ Snapshot sync points will now be displayed correctly.
◦ No snapshots will be taken after the schedule has expired.
◦ The controller will no longer hang when trying to add an invalid Remote Snap
destination-volume.
• The following fixes are specific to the Storage Management Utility (SMU):
The Provisioning wizard will now permit a vdisk to be created with 128 volumes.◦
◦ On the Add Remote System page, the Password field could be left blank. A valid entry is
now required.
◦ Reworded the message displayed for the Rename Host task.
◦ Online help was updated to reflect that no progress bar or message will be displayed when
a roll back is in progress.
◦ Single-ported SATA drives installed in cascaded HP D2700 drive enclosures will now show
the correct status information; they will no longer be displayed as “degraded”.
◦ Corrected name and fan information displayed for D2700 drive enclosures.
◦ When running the Verify Vdisk utility, the Abort Verify Vdisk button will no longer be
grayed-out.
• The following fixes are specific to the Command Line Interface (CLI):
For scripted CLI, removed an issue that caused the controller to crash and generate
communication errors.
◦
◦ set cache-parameters command: If the command syntax is correct, the “An invalid
device was specified” message will no longer be displayed.
◦ create vdisk command: The assigned-to parameter will now be ignored when in
single-controller mode.
◦ set cli-parameters command: Will now be recorded in the specified locale language,
not the previous locale language.
◦ set cli-parameters and show cli-parameters commands: Corrected wording
inconsistency in the online help.
◦ create volume-set command: Updated online help.
◦ vdisk shutdown command: A vdisk that has been stopped will now display the Status as
STOP, and the Health as Unknown.
◦ set advanced settings command: The following parameter settings are now recognized:
enable, enabled, disable, and disabled.
◦ show controllers command: Corrected the display to remove the possibility of a rare
display of an unclear error message.
◦ show replication-volumes command: Corrected the display.
◦ create user command: If conflicting base and storage-size-base parameters are
both set, an error message will now be displayed.
6 Fixes