EasyManua.ls Logo

HP ProDesk 600 G1 Small Form Factor - Appendix D Specifications; TWR Specifications

HP ProDesk 600 G1 Small Form Factor
243 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
D Specifications
TWR specifications
Chassis
Height
Width
Depth
15.7 in
6.7 in
17.4 in
39.9 cm
17.0 cm
44.2 cm
Approximate Weight 20.5 lb 9.3 kg
Temperature Range
Operating
Nonoperating
50° to 95°F
-22° to 140°F
10° to 35°C
-30° to 60°C
NOTE: Operating temperature is derated 1.0° C per 300 m (1000 ft) to 3000 m (10,000 ft) above sea level; no
direct sustained sunlight. Maximum rate of change is 10° C/Hr. The upper limit may be limited by the type and
number of options installed.
Relative Humidity (noncondensing)
Operating
Nonoperating (38.7°C max wet bulb)
10-90%
5-95%
10-90%
5-95%
Maximum Altitude (unpressurized)
Operating
Nonoperating
10,000 ft
30,000 ft
3048 m
9144 m
Power Supply
Operating Voltage Range
Rated Voltage Range
1
Rated Line Frequency
Operating Line Frequency
90-264 VAC
100-240 VAC
50-60 Hz
47-63 Hz
Standard Efficiency
High Efficiency
320W STD active PFC / 320W STD HV active PFC
320W 92% efficient active PFC / 320W 90%
efficient active PFC
226 Appendix D Specifications