EasyManua.ls Logo

HP ProLiant DL360 G7 - Operations; Power Up and Down the Server; Extend Server from Rack

HP ProLiant DL360 G7
24 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
No. Task Reference Avaya
recommendation
• DL360G7 SRVR
DUAL PORT 1GB
NIC
MSG: Removal and
replacement procedures:
PCI riser board
assembly
Expansion boards
PCIe riser board
Mark any cables
connected to the NIC
and reconnect to the
same ports after the NIC
is replaced.
The NIC requires a half-
HT faceplate. You might
need to remove the full
faceplate and replace it
with the half faceplate,
which requires a
crosshatch (Phillips)
screwdriver.
Note:
If adding a NICs:
populate PCI Slot 1
first, followed by Slot
2.
• DL360G7 SRVR
FAN FRU
MSG: Removal and
replacement procedures >
Fan module
Refer to the Systems
Insight Display LEDs to
identify the defective fan.
• DL360G7 SRVR
2GB MEMORY DIMM
• DL360G7 SRVR
4GB MEMORY DIMM
MSG: Removal and
replacement procedures >
DIMMs
Refer to the Systems
Insight Display LEDs to
identify the defective
DIMM.
Caution:
When removing the
air baffle, ensure that
the RAID battery does
not fall out of its
compartment in the
baffle.
Caution:
Refer to the
information on the top
of the air baffle and
inside cover for
correct DIMM
placement.
• DL360G7 SRVR
650 MAH RAID
BATTERY
MSG: Removal and
replacement procedures >
BBWC battery pack or
FBWC capacitor pack
Caution:
Consult the internal
label with directions
for removing the air
baffle. Be careful that
the RAID battery does
Replacing internal components
Maintaining and Troubleshooting the HP ProLiant DL360 G7 Server November 2010 19