No. Task Reference Avaya
recommendation
• DL360G7 SRVR DUAL
PORT 1GB NIC
TG: Expansion board problems Check NIC indicator
LEDs. If problem
persists, order
replacement NIC.
• DL360G7 SRVR FAN FRU TG: Fan problems If problem persists,
order replacement fan.
• DL360G7 SRVR 2GB
MEMORY DIMM
• DL360G7 SRVR 4GB
MEMORY DIMM
TG: Memory problems If problem persists,
order replacement
memory.
• DL360G7 SRVR 650 MAH
RAID BATTERY
3 If the part is defective, see
Replacing internal server
components.
Replacing external components
Use the checklist below to replace any of the following external server components:
Part number
Description Hot-swappable?
700501426 DL360G7 SRVR 146GB 10K SAS
2.5” HDD drive
Y
700501249 DL360G7 SRVR 146GB 15K SAS
2.5” HDD
Y
700501314 DL360G7 SRVR 300GB 10K SAS
2.5” HDD
Y
700501182 DL360G7 SRVR PWR SUP 460W
HE
Y, if redundant
700501312 DL360G7 SRVR AC PWR SUP
750W
Y, if redundant
700501313 DL360G7 SRVR DC PWR SUP
1200W
Y, if redundant
Note:
Hard disk drives and redundant power supplies are hot-swappable; you do not have to power
down the server. Replacing a power supply usually does not require removing the server from
the rack unless cables or other obstructions prevent removing and replacing the power supply.
Maintaining and Troubleshooting the HP DL360 G7 Server
12 Maintaining and Troubleshooting the HP ProLiant DL360 G7 Server November 2010
Comments on this document? infodev@avaya.com