BTUs per hour 2285 a
input
t 100V to 120V AC
2217 at 2 to 240V AC 00V
input
Power supply output
Rated steady-state power ation, see
ification
s (on
For more inform
“Power supply spec
page 81).”
Rated peak power n, see
s (on
For more informatio
“Power supply specification
page 81).”
*T t requirements are based on measurements using hardware available at the publication
of this document. For updated information, see the
HP website (http://www.hp.com/go/proliant-energy-
he system inpu
efficient).
Power supply specifications
The following specifications provide information on the parameters of the power supplies as they were
d information specific server, see the
HP website
(
http://www.hp.com/go/proli rgy-efficient
esigned. For more on configuring power for a
ant-ene ).
Depending on installed options h one of the following power supplies:
HP ProLiant 460 W Power Supply
, the server is configured wit
•
Specification Value
Input requirements
Rated input voltage 100V to 1 AC 20V
200V to 240V AC
Rated input frequency 50Hz to 60Hz
Rated input current 5.5A at 100V AC
2.6A at 200V AC
Rated input power input 526 W at 100V AC
505 W at 200V AC input
BTUs per hour 1794 at 100V AC input
1725 at 200V AC input
Power supply output
Rated steady-state power 460 W at 100V to 120V AC
input
C 460 W at 200V to 240V A
input
Rated peak power
460 W at 200V to 240V AC
input
460 W at 100V to 120V AC
input
Specifications 81