EasyManuals Logo

HP ProLiant series User Manual

HP ProLiant series
139 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #103 background imageLoading...
Page #103 background image
Error messages 103
Audible Beeps: None
Possible Cause: Upgrade the Array Accelerator module to a larger size.
Action: Migrate logical drives to RAID 0 or 1, reduce the number of drives in the array, or upgrade to a
larger-size array accelerator module.
1713-Slot Z Drive Array Controller - Redundant ROM Reprogramming Failure...
...Replace the controller if this error persists after restarting system.
Audible Beeps: None
Possible Cause: Flash ROM is failing. The controller detected a checksum failure, but is unable to
reprogram the backup ROM.
Action:
1. Update the controller to the latest firmware version.
2. If the problem persists, replace the controller.
1714-Slot Z Drive Array Controller - Redundant ROM Checksum Error...
...Backup ROM has automatically been activated. Check firmware version.
Audible Beeps: None
Possible Cause: The controller flash operation was interrupted by a power cycle, or flash ROM is
failing. The controller detected a ROM checksum error and automatically switched to the backup ROM
image.
Action: If this backup ROM image is a lower version than the originally running image, update the
controller to the latest firmware version.
1715-Slot X Drive Array Controller - Memory Error(s) Occurred
...Warning: Corrected Memory Error(s) were detected during controller memory self-test...
Audible Beeps: None
Possible Cause: The memory is beginning to fail.
Action: If this error persists, replace the controller.
1720-Slot X Drive Array - S.M.A.R.T. Hard Drive(s) Detect Imminent Failure SCSI: Port Y: SCSI ID
Z.
Audible Beeps: None
Possible Cause: A hard drive SMART predictive failure condition is detected. It may fail at some time in
the future.
Action:
If this drive is part of a non-fault-tolerant configuration, back up all data before replacing the drive
and restore all data afterward.
If this drive is part of a fault-tolerant configuration, do not replace this drive unless all other drives in
the array are online.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProLiant series and is the answer not in the manual?

HP ProLiant series Specifications

General IconGeneral
CategoryServer
SeriesProLiant
ManufacturerHP
Processor SupportIntel Xeon, AMD Opteron
Memory SupportDDR3, DDR4
Storage SupportSATA, SAS, SSD
Form FactorTower, Rackmount, Blade
NetworkingGigabit Ethernet, 10Gb Ethernet
ManagementiLO (Integrated Lights-Out)
Power SupplyRedundant power supply options
Operating System SupportWindows Server, Linux, VMware

Related product manuals