EasyManuals Logo

HP ProLiant series User Manual

HP ProLiant series
139 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #104 background imageLoading...
Page #104 background image
Error messages 104
1720-S.M.A.R.T. Hard Drive Detects Imminent Failure
Audible Beeps: None
Possible Cause: A hard drive SMART predictive failure condition is detected. It may fail at some time in
the future.
Action:
• If configured as a non-RAID 0 array, replace the failing or failed drive. Refer to the server
documentation.
• If configured as a RAID 0 array or non-RAID setup, back up the drive or drives, replace the drive,
and restore the system.
1721-Slot X Drive Array - Drive Parameter Tracking Predicts Imminent Failure...
...The following devices should be replaced when conditions permit. Do not replace drive unless all other drives in
the array are on-line! Back up data before replacing drive(s) if using RAID 0.
Audible Beeps: None
Possible Cause: Drive parameter tracking reports a predictive-failure condition on the indicated drive. It
may fail at some time in the future.
Action:
• If the drive is part of a non-fault-tolerant configuration, back up all data before replacing the drive
and restore all data afterward.
• If the drive is part of a fault-tolerant configuration, do not replace the drive unless all other drives in
the array are online.
1724-Slot X Drive Array - Physical Drive Position Change(s) Detected - ...
...Logical drive configuration has automatically been updated.
Audible Beeps: None
Possible Cause: The logical drive configuration has been updated automatically following physical
drive position changes.
Action: No action is required.
1725-Slot X Drive Array-Optional SIMM Failure Detected
Audible Beeps: None
Possible Cause: SIMM has been automatically disabled due to memory errors or unsupported SIMM
type installed.
Action: Replace the SIMM memory module on the indicated controller.
1726-Slot X Drive Array - Array Accelerator Memory Size Change Detected. - ...
...Array Accelerator configuration has automatically been updated.
Audible Beeps: None
Possible Cause: The array accelerator configuration has been updated automatically due to
replacement of the array accelerator (or controller) with one having different cache memory size.
Action: Run the ACU ("Array Configuration Utility" on page 49) to change the default cache read/write
allocation ratio.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProLiant series and is the answer not in the manual?

HP ProLiant series Specifications

General IconGeneral
CategoryServer
SeriesProLiant
ManufacturerHP
Processor SupportIntel Xeon, AMD Opteron
Memory SupportDDR3, DDR4
Storage SupportSATA, SAS, SSD
Form FactorTower, Rackmount, Blade
NetworkingGigabit Ethernet, 10Gb Ethernet
ManagementiLO (Integrated Lights-Out)
Power SupplyRedundant power supply options
Operating System SupportWindows Server, Linux, VMware

Related product manuals