EasyManuals Logo

HP ProLiant series User Manual

HP ProLiant series
139 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #105 background imageLoading...
Page #105 background image
Error messages 105
1727-Slot X Drive Array - New Logical Drive(s) Attachment Detected...
...If more than 32 logical drives, this message will be followed by: “Auto-configuration failed: Too many logical
drives.”
Audible Beeps: None
Possible Cause: The controller has detected an additional array of drives that was connected when the
power was off. The logical drive configuration information has been updated to add the new logical
drives. The maximum number of logical drives supported is 32. Additional logical drives will not be
added to the configuration.
Action: No action is required.
1729-Slot 1 Drive Array - Performance Optimization Scan In Progress...
...RAID 4/5/ADG performance may be higher after completion.
Audible Beeps: None
Possible Cause: RAID 4/5/ADG parity drive(s) are being initialized. Performance of the controller
improves after the parity data has been initialized by ARM (an automatic process that runs in the
background on the controller).
Action: No action is required.
1754-Slot X Drive Array - RAID ADG configured but ADG is not supported on this controller
model.
Audible Beeps: None
Possible Cause: RAID ADG configured by ADG is not supported on this controller model.
Action: Replace the controller with a model that supports RAID ADG.
1762-Slot X Drive Array - Controller Firmware Upgrade Needed
Audible Beeps: None
Possible Cause: Different firmware versions are running on the base controller and the expansion
module controller.
Action: Upgrade the firmware on both the SA6400 base controller and SA6400 expansion module
controller to the same version.
1763-Array Accelerator Daughtercard is Detached; Please Reattach
Audible Beeps: None
Possible Cause: Array accelerator module is loose, missing, or defective.
Action:
1. Reseat array accelerator module.
2. If the problem persists, replace the array accelerator module.
1764-Slot X Drive Array - Capacity Expansion Process is Temporarily Disabled...
(followed by one of the following)
...Expansion will resume when Array Accelerator has been reattached.
Expansion will resume when Array Accelerator has been replaced.
Expansion will resume when Array Accelerator RAM allocation is successful.
Expansion will resume when Array Accelerator battery reaches full charge.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProLiant series and is the answer not in the manual?

HP ProLiant series Specifications

General IconGeneral
CategoryServer
SeriesProLiant
ManufacturerHP
Processor SupportIntel Xeon, AMD Opteron
Memory SupportDDR3, DDR4
Storage SupportSATA, SAS, SSD
Form FactorTower, Rackmount, Blade
NetworkingGigabit Ethernet, 10Gb Ethernet
ManagementiLO (Integrated Lights-Out)
Power SupplyRedundant power supply options
Operating System SupportWindows Server, Linux, VMware