EasyManuals Logo

HP ProLiant series User Manual

HP ProLiant series
139 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #106 background imageLoading...
Page #106 background image
Error messages 106
Expansion will resume when automatic data recovery has been completed.
Audible Beeps: None
Possible Cause: The capacity expansion process has been temporarily disabled.
Action: Follow the action that is displayed onscreen to resume the capacity expansion process.
1753-Slot Z Drive Array - Array Controller Maximum Operating Temperature Exceeded During
Previous Power Up
Audible Beeps: None
Possible Cause: Controller is overheating.
Action: Be sure adequate system cooling and sufficient airflow across controller are available.
1768-Slot X Drive Array - Resuming Logical Drive Expansion Process
Audible Beeps: None
Possible Cause: Power was lost while a logical expansion operation was performed. A controller reset
or power cycle occurs while array expansion is in progress.
Action: No action is required.
1769-Slot X Drive Array - Drive(s) Disabled Due to Failure During Capacity Expansion
...Select F1 to continue with logical drives disabled. Select F2 to accept data loss and to re-enable logical drives.
Audible Beeps: None
Possible Cause: Data was lost while the array was expanded; therefore, the drives have been
temporarily disabled. Capacity expansion failed due to:
Array accelerator or hard drive failed or was removed; expansion progress data lost
Expansion progress data could not be read from array accelerator
Expansion aborted due to unrecoverable drive errors
Expansion aborted due to array accelerator errors
Action:
Press the F2 key to accept the data loss and re-enable the logical drives.
Restore data from backup.
Replace drive or array accelerator, as appropriate.
1770-Slot X Drive Array - SCSI Drive Firmware Update Recommended - ...
...Please upgrade firmware on the following drive(s) using ROM Flash Components (download from
www.hp.com/support/proliantstorage): Model XYZ (minimum version = ####)
Audible Beeps: None
Possible Cause: Drive firmware update needed.
Action: The indicated drives are running firmware that is known to cause intermittent problems. Update
all drives to the latest firmware version.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProLiant series and is the answer not in the manual?

HP ProLiant series Specifications

General IconGeneral
CategoryServer
SeriesProLiant
ManufacturerHP
Processor SupportIntel Xeon, AMD Opteron
Memory SupportDDR3, DDR4
Storage SupportSATA, SAS, SSD
Form FactorTower, Rackmount, Blade
NetworkingGigabit Ethernet, 10Gb Ethernet
ManagementiLO (Integrated Lights-Out)
Power SupplyRedundant power supply options
Operating System SupportWindows Server, Linux, VMware

Related product manuals