Error messages 129
Interconnect B Error Code
LED code: 14-1, 14-2, 14-3, or 14-4
Location: Interconnect device - side B
Action: Perform the following steps to resolve the problem. Stop when the problem is resolved.
1. Press the server blade management module reset button.
2. Reseat the interconnect device.
For more information, refer to the HP BladeSystem Maintenance and Service Guide on the HP
website (http://www.hp.com/products/servers/proliant-bl/p-class/info
).
3. Replace the interconnect device.
For more information, refer to the HP BladeSystem Maintenance and Service Guide on the HP
website (http://www.hp.com/products/servers/proliant-bl/p-class/info
).
Interconnect Module A (10-Connector) Error Code
LED code: 15-1 or 15-2
Location: Interconnect module - side A (10-connector)
Action: Perform the following steps to resolve the problem. Stop when the problem is resolved.
1. Press the server blade management module reset button.
2. Reseat the interconnect module.
For more information, refer to the HP BladeSystem Maintenance and Service Guide on the HP
website (http://www.hp.com/products/servers/proliant-bl/p-class/info
).
3. Replace the interconnect module.
For more information, refer to the HP BladeSystem Maintenance and Service Guide on the HP
website (http://www.hp.com/products/servers/proliant-bl/p-class/info
).
Interconnect Module A (6-Connector) Error Code
LED code: 17-1 or 17-2
Location: Interconnect module - side A (6-connector)
Action: Perform the following steps to resolve the problem. Stop when the problem is resolved.
1. Press the server blade management module reset button.
2. Reseat the interconnect module.
For more information, refer to the HP BladeSystem Maintenance and Service Guide on the HP
website (http://www.hp.com/products/servers/proliant-bl/p-class/info
).
3. Replace the interconnect module.
For more information, refer to the HP BladeSystem Maintenance and Service Guide on the HP
website (http://www.hp.com/products/servers/proliant-bl/p-class/info
).
Interconnect Module B (10-Connector) Error Code
LED code: 16-1 or 16-2
Location: Interconnect module - side B (10-connector)
Action: Perform the following steps to resolve the problem. Stop when the problem is resolved.
1. Press the server blade management module reset button.
2. Reseat the interconnect module.