EasyManua.ls Logo

HP ProLight Server

HP ProLight Server
152 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Error messages 135
Description: The system encountered an NMI prior to this boot. The NMI source was: Uncorrectable
cache memory error.
Action: Replace the processor.
Insight Diagnostics processor error codes
MSG_CPU_RR_1
Event type: Unable to divide and multiply with zero and infinity.
Action:
Ensure proper ventilation and cooling for the server.
Ensure the processor heatsinks are attached correctly (do not remove them).
Check diagnostics and the Integrated Management Log for heat-related events.
Upgrade to the latest versions of system BIOS and Insight Diagnostics.
Replace the processor.
MSG_CPU_RR_2
Event type: A Pentium floating point bug exists.
Action: Replace the processor.
MSG_CPU_RR_3
Event type: Coprocessor geometric series is out of range.
Action:
Ensure proper ventilation and cooling for the server.
Ensure the processor heatsinks are attached correctly (do not remove them).
Check diagnostics and the Integrated Management Log for heat-related events.
Upgrade to the latest versions of system BIOS and Insight Diagnostics.
Replace the processor.
MSG_CPU_RR_5
Event type: Refresh count is out of range.
Action: Replace the board that contains the memory controller.
MSG_CPU_RR_6
Event type: Unable to perform arithmetic operations on registers.
Action:
Ensure proper ventilation and cooling for the server.
Ensure the processor heatsinks are attached correctly (do not remove them).
Check diagnostics and the Integrated Management Log for heat-related events.
Upgrade to the latest versions of system BIOS and Insight Diagnostics.
Replace the processor.

Table of Contents

Related product manuals