The HP StorageWorks 50 Modular Smart Array (MSA50) Enclosure is a 1U Serial Attach SCSI(SAS) disk drive storage
enclosure supporting Small Form Factor(SFF) SAS or Serial ATA(SATA) drives. This enclosure delivers industry-leading
data performance, availability, storage density, and upgradeability to meet customers' demanding and growing storage
needs. The all new SFF drive carrier is designed to support the new Universal form factor hard drive in either SAS or SATA.
This new form factor provides optimized performance per U of space while delivering unparalleled power consumption. The
MSA50 enclosure supports direct attach storage to HP ProLiant and Integrity Servers. The MSA50 supports the cascading
of shelves in a 1+1 configuration to allow a maximum of 20 SFF drives in a 2U configuration attached to a single controller
port. This single controller port incorporates four lanes for a total max throughput of 12Gb/s for SAS.
1.
Expansion slot for potential future second I/O
6.
Power button/LED
2.
Fan
7.
UID button/LED
3.
Hot-plug power supply
8.
Hot-plug SAS or SATA hard drive bays
4.
Hot-plug power supply
9.
Access panel
5.
I/O module
Models
The MSA50 design allows for the mix of SAS and SATA drives in the same enclosure at the same time and is tailored to the
needs of HP server customers who require optimized performance per U of rack space.
Model MSA50
HP StorageWorks 50 Modular Smart Array Enclosure
NOTE:
Rack-mountable 10 SFF drive enclosure with single I/O module,
redundant hot plug power supplies and hot plug fans.
364430-B21
NOTE:
For complete compatibility information, refer to the Specifications section
of this document. SAS/SATA performance requires a compatible SAS controller.
This is noted in the product documentation.
QuickSpecs
HP StorageWorks Modular Smart Array 50
Enclosure
Overview
DA - 12245 U.S. QuickSpecs — Version 15 — 10/26/2007
Page 1
Question and Answer IconNeed help?

Do you have a question about the HP StorageWorks MSA50 and is the answer not in the manual?

Overview

The HP StorageWorks 50 Modular Smart Array (MSA50) Enclosure is a 1U Serial Attached SCSI (SAS) disk drive storage enclosure designed to support Small Form Factor (SFF) SAS or Serial ATA (SATA) drives. This enclosure is engineered to deliver industry-leading data performance, availability, storage density, and upgradeability to meet the demanding and growing storage needs of customers.

Function Description:

The MSA50 enclosure serves as a direct attach storage solution for HP ProLiant and Integrity Servers. It supports a mix of SAS and SATA drives within the same enclosure, offering flexibility for tiered storage solutions where reliability (SAS) and lower cost (SATA) can be balanced. The enclosure's modular design allows it to be integrated into various storage configurations, from Just a Bunch of Disks (JBOD) to Smart Array storage enclosures, and provides a potential path for future storage consolidation to a Storage Area Network (SAN).

The enclosure features a new Universal SFF drive carrier, designed to accommodate both SAS and SATA hard drives. This universal form factor optimizes performance per unit of rack space while also contributing to unparalleled power consumption efficiency. The MSA50 supports cascading shelves in a 1+1 configuration, enabling a maximum of 20 SFF drives in a 2U configuration to be attached to a single controller port. This single controller port incorporates four lanes, providing a total maximum throughput of 12Gb/s for SAS.

Important Technical Specifications:

  • Form Factor: 1U rack height
  • Drive Support: Up to 10 SFF SAS and/or SATA Universal hard disk drives
  • Storage Capacity: Up to 1.4TB per enclosure (using 146GB 10K disk drives); Cascadable 1+1 for up to 20 spindles in a 2U configuration or 2.8TB.
  • Data Transfer Rates: 3Gb/s for SAS and 1.5Gb/s for SATA
  • Protocol Support: 3Gb/s SAS, 1.5Gb/s SATA
  • I/O Module: Single I/O module installed, allowing one SAS controller to access all drives in the MSA50. The I/O module connector is SAS SFF 8470.
  • Power Supply: Redundant 180 Watts per supply (load)
  • Input Requirements:
    • Nominal Line Voltage: 110 to 240 V AC
    • Range Line Voltage: 90 to 264 V AC
    • Line Frequency: 47 to 63 Hz
    • Typical Input Current: 2.3A at 120 V AC
  • Environmental Monitoring: Equipped with an Environment Monitoring Unit (EMU) that constantly monitors the enclosure, power supplies, and fans to ensure suggested operating tolerances are maintained.
  • Operating Temperature: 50° to 94° F (10° to 35° C°)
  • Shipping Temperature: -40° to 151° F (-40° to 66° C)
  • Operating Relative Humidity (non-condensing): 10% to 90%
  • Shipping Relative Humidity (non-condensing): 5% to 90%
  • Dimensions (HxWxD):
    • Shipping Dimensions: 12 x 23.5 x 33 in (30.24 x 59.22 x 83.16 cm)
    • Redundant Power Supply Shipping Dimensions: 12.75 x 8 x 3.75 in (32.13 x 20.16 x 9.45 cm)
  • Weight:
    • Unloaded: 20 lb (9.07 kg)
    • Loaded: 30 lb (13.61 kg)
  • RAID Support: When used with an internal host-based controller, the MSA50 can be configured for RAID levels 0, 1, 1+0, 5, 6 (RAID ADG) using an HP Smart Array RAID controller.
  • Operating System Support: Defined by the specific HP array controller or SAS/SATA adapter used.

Usage Features:

  • Auto SAS ID Selection: SAS ID is automatically set when a drive is inserted into a drive bay.
  • LED Indicators: Front panel LEDs indicate drive activity, required drive service, and power, providing a quick visual assessment of overall system storage status. Drive LED indicators (on drive trays) show On-line/Activity (top) and Drive Fault/Locate (bottom). Enclosure Button/LED indicators (back of unit) include UID Button (top), System FRU (middle), and EMU Status LED (bottom).
  • Buttons: UID Button (top) and Fault LED (bottom) are present on the front right panel.
  • Rack Density: The MSA50 Enclosure has a 1U height, optimizing rack space utilization.
  • Mix and Match Drive Types: A common physical connection allows both SAS and SATA drive types to be mixed on the same backplane, offering flexibility for tiered storage and simplifying technology transitions.
  • Manageability: The MSA50 is managed by HP Systems Insight Manager.
  • Compatibility and Integration Testing: Intensive compatibility and performance testing with HP ProLiant servers ensures a high level of integration.
  • Product Kit Contents: Includes redundant power supplies, single I/O module, 9 drive blanks, warranty card, mounting hardware, Enclosure user guide, HP SmartStart CD Kit, documentation CD, one 2 Meter SAS external cable, two Nema 5-15 to C13 power cords, and two IEC320-C14 to -C13 power cords. Note: The included SAS cable is only for the P600 controller. Specific cables are required for Smart Array P800 or E500 controllers.

Maintenance Features:

  • Hot Pluggable Components: Drives, fans, and redundant power supplies are hot-pluggable, allowing replacement without powering down the storage system or stopping I/O operations, significantly enhancing data availability.
  • Field Replaceable Units (FRUs): Fans, I/O Module, and mid-plane are field replaceable.
  • Easy Serviceability: Easy removal of parts requires no tools, improving serviceability.
  • Upgradeability: Potential upgrade path for the I/O Module by swapping it out on the back of the unit (requires powering down the unit).
  • Fault Tolerance: Redundant power supplies and fans provide a high level of system availability.
  • Warranty: Three-year limited parts-only warranty, including hardware diagnostic support and pre-failure warranty for hard drives, memory, and processors. SAS drives have a 3-year warranty, while SATA drives have a 1-year warranty. Hard drive Pre-Failure Warranty is supported when used with StorageWorks Smart Array Family controllers and monitored under HP Systems Insight Manager (v4.20 or later).
  • Cooling and Airflow: To maintain proper cooling and airflow, a drive blank or drive must occupy all bays during operation.

HP StorageWorks MSA50 Specifications

General IconGeneral
BrandHP
ModelStorageWorks MSA50
CategoryEnclosure
LanguageEnglish