Figure 6: Inserting a p1228 card
6. Make sure the card is connected to the SuperCapacitor module and to the external SAS data storage.
7. Replace the cover, as described in the appropriate HPE ProLiant Maintenance and Service guide, and
power on the HPE StoreOnce Backup system.
8. Once rebooted, the HPE StoreOnce Backup system will identify the new RAID controller and will
remap the existing disk storage volumes and enclosures to the controller. It will take 5 to 10 minutes
for the process to complete. During this time the product will be online but several warning events will
be generated and the GUI Event Log will show errors being reported and cleared.
9. Use the StoreOnce GUI or StoreOnce CLI to check that the firmware on the new component is correct.
See Upgrading BIOS or hardware firmware components on page 16.
NOTE: Note the output at command completion. It will advise if you need a system reboot or a cold
reboot to install the new firmware revision successfully.
34 The HP p1228 RAID controller