10. If you are using HPE StoreOnce Remote Support, to return to normal mode after maintenance, run
the StoreOncCLI command:
11. system disable remoteeventsuppression "Disk Maintenance"
Rebuilding storage if multiple disks fail and a RAIDset is
broken
This section explains how to rebuild your storage in the event of a complete data loss. This should be
done under the guidance of HPE Support.
After the failed disks have been replaced it will be necessary to remove the old filesystem configuration
and rebuild a new one as follows:
Procedure
1. Use the following StoreOnce CLI to remove all configured storage on the appliance (except that used
by the operating system):
hardware delete storage all
WARNING: This command will completely remove all configured storage, and will run at any
time even if the storage is healthy.
This will clean up all filesystem configuration and delete logical drives (LUNs) on all storage
devices.
2. After the delete command has completed rebuild the storage system using the following StoreOnce
CLI commands to discover and add storage to the system
hardware discover storage
hardware add storage
This will configure both the storage in the appliance (base storage) and any attached expansion
shelves. Licenses must be present for all attached storage before the command will complete
successfully. If insufficient licenses are available, no storage will be configured.