CAUTION:
• If the switch is to be shipped in a rack, use only J9852A HPE X450 4U/7U Universal 4-Post
Rack Mounting Kit for each switch. The switch is qualified for rack shipping only in Hewlett
Packard Enterprise Shock Racks.
• Ensure the power source circuits are properly grounded.
• If your installation requires a different power cord than the one supplied with the switch and
power supply, be sure the cord is adequately sized for the switch’s current requirements. In
addition, be sure to use a power cord displaying the mark of the safety agency that defines
the regulations for power cords in your country. The mark is your assurance that the power
cord can be used safely with the switch and power supply.
• When installing the switch, note that the AC outlet should be near the switch and should be
easily accessible in case the switch must be powered off.
• Ensure the switch does not overload the power circuits, wiring, and over-current protection.
Each power supply should be connected to a dedicated branch circuit to prevent tripping
building circuit breakers. To determine the possibility of overloading the supply circuits, add
together the ampere ratings of all devices installed on the same circuit as the switch and
compare the total with the rating limit for the circuit. The maximum ampere ratings are usually
printed on the devices near the AC power connectors.
• Do not install the switch in an environment where the operating ambient temperature might
exceed 45°C (113°F).
• Allow at least three inches of space around the sides and back of the switch to make sure
the air flow for the switch is not restricted.
Regulatory information
WARNING! Do not wall-mount any of the 5400R zl2 switches or bundles.
HPE 5406R zl2 (J9821A) and 5412R zl2 Switches
(J9822A) including all bundlesApplicable Products
0°C to 45°C (32°F to 113°F)Environmental Operating Temperature:
15% to 95% at 45°C (113°F) (non-condensing)Relative humidity:
-40°C to 85°C (-40°F to 185°F)Non-Operating Temperature:
15% to 95% at 65°C (149°F)Non-Operating Relative humidity:
3.1 km (10,000 ft)Maximum Operating Altitude:
NOTE: If you are using the J9830B power supply unit
with your switch, the maximum operating temperature is
reduced to 40°C between altitudes of 5000 feet (1.52 km)
and 10000 feet (3.1 km).
15.24 km (50,000 ft)Non-Operating Altitude:
EN60950-1:2006+A11:2009+A1:2010+A12:2011 /
IEC60950-1:2005; Am1:2009; CSA22.2 No. 60950-1-07
2nd; UL60950-1 2nd
Safety Standards:
EN60825-1:2007 / IEC 60825-1:2007 Class 1Lasers:
Class 1 Laser Products/Laser Klasse 1
(Use only Hewlett Packard Enterprise supported SFPs)
Regulatory information 7