HPE ProLiant MicroServer Generation 8 (Gen8)
9.15 x 9.06 x 9.65 in (23.24x 23 x 24.5 cm)
Weight (approximate)
Maximum
(all hard drives, power supply
21.60 lb (9.8 kg)
Minimum
(one hard drive, power supply,
15.13 lb (6.8 kg)
Input Requirements
(per power supply)
Rated Line Voltage 100 -- 127 VAC,
Rated Input Current 3.5 A (at 110 VAC),
Rated Input Power For 150W Power Supply
192 W (at 100 VAC),
185 W (at 200 VAC)
For 200W Power Supply
243 W (at 100 VAC),
BTU Rating
Maximum For 150 W Power Supply
682 BTU/hr (at 100 VAC),
665 BTU/hr (at 200 VAC)
For 200 W Power Supply
838.86 BTU/hr (at 100 VAC),
825.22 BTU/hr (at 200 VAC)
Power Specifications
To review typical system power ratings use the Power Advisor which is
available via the online tool located at URL:
http://www.hp.com/go/hppoweradvisor
Power Supply Output
(per power supply)
Rated Steady-State Power For 150 W Power Supply
150 W (at 100 VAC),
150 W (at 200 VAC)
For 200 W Power Supply
200 W (at 100 VAC),
Maximum Peak Power For 150 W Power Supply
150 W (at 100 VAC),
150 W (at 200 VAC)
For 200 W Power Supply
200 W (at 100 VAC),
System Inlet
Temperature
Operating 10° to 35°C (50° to 95°F) at sea level with
an altitude derating of 1.0°C per every 305
m (1.8°F per every 1000 ft) above sea level
to a maximum of 3050 m (10,000 ft), no
direct sustained sunlight. Maximum rate of