Chapter 10 Parameter Shenzhen Hpmont Technology Co., Ltd.
-72- HD09 Series User Manual V1.1
Ref. Code
Function
Setting Range
Default
Unit
Attribute
Setting
Thousands: Switch the frequency
channel to the analogue selection
0: Not save
1: Save
F00.15
Jog operation frequency
digital setting
0.0 - up limitation (F00.08) 5.0Hz 0.1Hz
F00.17
Running direction
selection
0: Same direction
1:Reserved direction
0 1
×
F00.19
Dead time of direction
switch
0.0 - 3600.0s 0.0s 0.1s
×
F00.20 Keypad enbale
Unit: Button enbale
0: Enable
1: Disable
Ten: Potentiometer enbale
0: Potentiometer priority for keypad
1: Potentiometer with keypad
2: Potentiometer with external keypad
00 1
F00.21 Sleep function enbale
0: Disable
1: Enable 1
2: Enable 2
0 1
×
F00.22 Dormant wake time 0.0 - 360.0s 0.0s 0.1s
×
F00.24 Sleep delay 0.0 - 3600.0s 0.0s 0.1s
×
F00.25 Sleep frequency 0.0Hz - F00.08 0.5Hz 0.1Hz
F01: Parameter Protection function
F01.00 User’s password 00000 - 65535 00000 1
F01.01 Menu mode selection
0: Full menu mode
1: Checking menu mode
0 1
F01.02
Function codeparameter
initialization (parameter
download)
0: No operation
1: Restore to factory settings
2/3: Keypad stored parameter 1/2
iscopied to control board and update
current function value
4: Clear fault information
0 1
×
F01.03
Copy parameter to keypad
(parameter uploading)
0: No operation
1/2: Current function values are copied
to keypad stored parameter 1/2
0 1