HD09 Series
Smart Inverter
User Manual
Single-phase 220 - 240V, 0.25 - 2.2kW
Three-phase 380 - 460V, 0.4 - 5.5kW

Table of Contents

Questions and Answers

  • T
    Travis ClaytonSep 17, 2025
    How to fix SCI communication time-out on hpmont HD09-2S2P2G Inverter?
    • T
      Tammie MoralesSep 18, 2025
      If your hpmont Inverter is experiencing SCI communication time-out, there may be a connection fault with the communication cable or the cable is disconnected or not well connected, so please check the connection.
  • S
    Sandra ReyesAug 25, 2025
    What to do if hpmont HD09-2S2P2G Inverter shows DC bus over voltage during acceleration?
    • J
      josealvarezAug 25, 2025
      If your hpmont Inverter displays a DC bus acceleration overvoltage error, it could be due to several factors: the input voltage being too high, a deceleration time set too short, improper wiring leading to hardware overvoltage, or an incorrect selection of braking devices. Here’s how to address it: * Verify the power input. * Set a proper value for deceleration time using parameter F03.02. * Inspect the wiring and ensure it is correctly wired. * Select braking devices according to the recommendations.
  • E
    Eric CowanAug 25, 2025
    How to fix hpmont Inverter acceleration overcurrent?
    • T
      Tyler CarterAug 26, 2025
      Inverter acceleration overcurrent in your hpmont device can occur due to improper connection between the inverter and motor, incorrect motor parameters, an inverter rating that's too small, or an acceleration/deceleration time that's too short. Here’s how to troubleshoot: * Ensure the inverter and motor are properly connected. * Set the correct motor parameters using settings F08.00 - F08.03. * Choose an inverter with a higher rating. * Set appropriate acceleration and deceleration times (F03.01, F03.02).
  • L
    lhernandezAug 26, 2025
    Why is my hpmont Inverter motor overloading?
    • D
      Darlene HubbardAug 26, 2025
      Your hpmont Inverter's motor might be overloading due to an improper setting of the V/f curve, low mains supply voltage, prolonged operation with a heavy load at low speed, or blocked torque/excessive load. To resolve this: * Adjust the setting of the V/f curve using parameters F09.01 - F09.06. * Check the power input. * Consider using a special motor. * Inspect the load and mechanical transmission devices.
  • G
    george95Sep 18, 2025
    What does CPU fault mean on hpmont Inverter?
    • R
      Ryan SawyerSep 18, 2025
      If your hpmont Inverter is showing a CPU fault, it indicates the CPU is abnormal, so please detect at power on after completely power outage. If the issue persists, please seek technical support.
  • A
    Ashley SanchezSep 23, 2025
    What to do if there is fault of current detection circuit in hpmont HD09-2S2P2G?
    • O
      owardSep 23, 2025
      If your hpmont Inverter indicates a fault in the current detection circuit, it means the current detection circuit is damaged, so please contact the supplier for repairing.
  • M
    Mr. Joseph GuzmanSep 9, 2025
    What causes motor overload on hpmont HD09-2S2P2G?
    • T
      Taylor RileySep 9, 2025
      If the hpmont Inverter indicates a motor overload, the V/f curve setting might be incorrect, so adjust the setting of V/f curve (F09.01 - F09.06). The mains supply voltage might be too low, so check the power input. It's possible the motor is running for a long time with a heavy load at low speed, so please use a special motor. Also, the motor might be running with blocked torque or the load is too heavy, so check the load and mechanical transmission devices.
  • M
    Michael FrazierSep 10, 2025
    What to do for DC bus acceleration over voltage on hpmont HD09-2S2P2G?
    • J
      Joseph BridgesSep 10, 2025
      If your hpmont Inverter shows a DC bus acceleration overvoltage, the input voltage might be too high, so please check the power input. The deceleration time might be too short, so set a proper value for deceleration time (F03.02). Improper wiring could lead to overvoltage of hardware, so check the wiring and wire the inverter properly. It may also be due to improper selection of the braking devices, so select according to the recommended braking devices of section 5.2 Braking Resistor, page 16.
  • J
    Jill HunterSep 3, 2025
    What causes SCI communication time-out in hpmont Inverter?
    • B
      balldeannaSep 3, 2025
      SCI communication time-out with your hpmont Inverter can be caused by a connection fault in the communication cable, or if the cable is disconnected or not well connected. To resolve this, check the connection.
  • M
    Mikayla StanleySep 1, 2025
    What to do if hpmont HD09-2S2P2G parameters auto-tuning fault?
    • B
      Brittany ZunigaSep 1, 2025
      If your hpmont Inverter's parameter auto-tuning fails, it is likely due to the parameter auto-tuning timing out. To address this: * Check the motor’s connection. * Input the correct motor parameters using settings F08.01 - F08.03.

Summary

Chapter 1 Safety Information

Safety Definition

Explains safety symbols and their meanings in the manual.

Chapter 3 Machenical Installation

3.2 Requirement for the Installation Site

Specifies environmental and spatial requirements for safe and optimal inverter installation.

Chapter 4 Electrical Installation

4.1 Electric Requirements

Covers essential grounding and wiring specifications, including cable distribution.

4.2 Power Terminals and Connection

Describes power terminal connections for different inverter sizes (Size A and B).

4.3 Control Terminals and Connection

Details the wiring and connection of various control terminals and their functions.

Chapter 6 Operation

Chapter 7 Detailed Function Introduction

7.1 F00: Basic Parameter

Covers fundamental parameters like output frequency, operation modes, and frequency save settings.

7.8 F08: Motor Parameter

Details essential motor parameters (power, voltage, current, RPM) and the auto-tuning function.

7.9 F09: V;f Controlling Parameter

Covers V/f control parameters, defining voltage/frequency curves, and torque boost settings.

7.10 F15: Digital Input; Output Terminals Parameter

Describes functions for digital input and output terminals, including selection, logic, and specific uses.

7.11 F16: Analogue Input; Output Terminal Parameter

Details parameters for analog input/output terminals, including filtering, gain, and polarization.

7.15 F20: Fault Protection Parameter

Details overload protection, phase fault detection, and automatic fault reset functions.

Chapter 8 Troubleshooting and Maintenance

8.1 Troubleshooting

Lists common faults, their reasons, and corresponding countermeasures for quick resolution.

Chapter 9 MODBUS Communication Protocol

hpmont HD09-2S2P2G Specifications

General IconGeneral
USB Output5V/2.1A
CategoryInverter
Input Voltage12V DC
Output Voltage220V AC
ProtectionOverload, Over Voltage, Over Temperature, Short Circuit