Questions and Answers

  • N
    nobleglennSep 12, 2025
    How to resolve stall overvoltage on hpmont Inverter?
    • E
      eric98Sep 12, 2025
      If your hpmont Inverter is experiencing stall overvoltage, the bus voltage might be too high, so check the power input or the function of the brake. Alternatively, the setting of stall overvoltage might be too low, so set the value of stall overvoltage properly (F19.19).
  • J
    jshieldsSep 12, 2025
    What causes fault of power module in hpmont Inverter?
    • J
      Jeff HernandezSep 12, 2025
      If your hpmont Inverter reports a fault in the power module, there might be a short circuit between phases output, so check the connection and connect the wire properly. There could be a short circuit to the ground, so check the connection and connect the wire properly. The output current might be too high, so check the connection and mechanism. The power module itself might be damaged, so please contact the supplier for repairing.
  • M
    Michael FrazierSep 10, 2025
    What to do for DC bus acceleration over voltage on hpmont HD09-2S2P2G?
    • J
      Joseph BridgesSep 10, 2025
      If your hpmont Inverter shows a DC bus acceleration overvoltage, the input voltage might be too high, so please check the power input. The deceleration time might be too short, so set a proper value for deceleration time (F03.02). Improper wiring could lead to overvoltage of hardware, so check the wiring and wire the inverter properly. It may also be due to improper selection of the braking devices, so select according to the recommended braking devices of section 5.2 Braking Resistor, page 16.
  • M
    Mr. Joseph GuzmanSep 9, 2025
    What causes motor overload on hpmont HD09-2S2P2G?
    • T
      Taylor RileySep 9, 2025
      If the hpmont Inverter indicates a motor overload, the V/f curve setting might be incorrect, so adjust the setting of V/f curve (F09.01 - F09.06). The mains supply voltage might be too low, so check the power input. It's possible the motor is running for a long time with a heavy load at low speed, so please use a special motor. Also, the motor might be running with blocked torque or the load is too heavy, so check the load and mechanical transmission devices.
  • R
    Richard GuzmanSep 8, 2025
    Why is my hpmont HD09-2S2P2G heatsink overheating?
    • C
      Catherine WalkerSep 8, 2025
      If your hpmont Inverter's heatsink is overheating, the ambient temperature might be too high, so consider using an inverter with higher power capacity. The inverter's external ventilation might be poor, so improve the ventilation around it. There could be a fan fault, so replace the cooling fan. It may also be a fault in the temperature detection circuit, so please seek technical support.
  • C
    Christy JohnsonAug 23, 2025
    Why is my hpmont Inverter overloading?
    • B
      Brandon WagnerAug 23, 2025
      An hpmont Inverter might overload due to several reasons: the acceleration time being too short, improper settings of the V/f curve or torque boost leading to overcurrent, low mains supply voltage, or the motor load being too high. To resolve this, try the following: * Adjust the acceleration time using parameter F03.01. * Adjust the V/f curve (F09.01 - F09.06) or torque boost (F09.07, F09.08). * Check the mains supply voltage. * Use an inverter with a proper power rating.
  • B
    Brandi FlemingSep 6, 2025
    What to do if my hpmont HD09-2S2P2G Inverter is overloaded?
    • R
      Robert ReynoldsSep 6, 2025
      If your hpmont Inverter is overloaded, it could be due to several reasons. The acceleration time might be too short, so adjust the acceleration time using parameter F03.01. The V/f curve or torque boost settings might be causing overcurrent, so adjust the V/f curve (F09.01 - F09.06) or torque boost (F09.07, F09.08). Also, check the mains supply voltage and ensure it's adequate. If the motor load is too high, consider using an inverter with a proper power rating.
  • G
    Guy HendersonSep 5, 2025
    What to do if hpmont HD09-2S2P2G Inverter shows Fault of external equipment?
    • K
      Kelly SmithSep 5, 2025
      If your hpmont Inverter indicates a fault with external equipment due to a fault terminal operating, check the external equipment.
  • J
    Joseph TaylorSep 4, 2025
    What to do if hpmont HD09-2S2P2G contactor is not actuated?
    • I
      Ian MccormickSep 4, 2025
      If the contactor in your hpmont Inverter is not actuating, it could be due to a contactor fault or a fault in the control circuit. To address this, replace the contactor.
  • J
    Jill HunterSep 3, 2025
    What causes SCI communication time-out in hpmont Inverter?
    • B
      balldeannaSep 3, 2025
      SCI communication time-out with your hpmont Inverter can be caused by a connection fault in the communication cable, or if the cable is disconnected or not well connected. To resolve this, check the connection.

Summary

Chapter 1 Safety Information

Safety Definition

Explains safety symbols and their meanings in the manual.

Chapter 3 Machenical Installation

3.2 Requirement for the Installation Site

Specifies environmental and spatial requirements for safe and optimal inverter installation.

Chapter 4 Electrical Installation

4.1 Electric Requirements

Covers essential grounding and wiring specifications, including cable distribution.

4.2 Power Terminals and Connection

Describes power terminal connections for different inverter sizes (Size A and B).

4.3 Control Terminals and Connection

Details the wiring and connection of various control terminals and their functions.

Chapter 6 Operation

Chapter 7 Detailed Function Introduction

7.1 F00: Basic Parameter

Covers fundamental parameters like output frequency, operation modes, and frequency save settings.

7.8 F08: Motor Parameter

Details essential motor parameters (power, voltage, current, RPM) and the auto-tuning function.

7.9 F09: V;f Controlling Parameter

Covers V/f control parameters, defining voltage/frequency curves, and torque boost settings.

7.10 F15: Digital Input; Output Terminals Parameter

Describes functions for digital input and output terminals, including selection, logic, and specific uses.

7.11 F16: Analogue Input; Output Terminal Parameter

Details parameters for analog input/output terminals, including filtering, gain, and polarization.

7.15 F20: Fault Protection Parameter

Details overload protection, phase fault detection, and automatic fault reset functions.

Chapter 8 Troubleshooting and Maintenance

8.1 Troubleshooting

Lists common faults, their reasons, and corresponding countermeasures for quick resolution.

Chapter 9 MODBUS Communication Protocol

hpmont HD09-2S2P2G Specifications

General IconGeneral
USB Output5V/2.1A
CategoryInverter
Input Voltage12V DC
Output Voltage220V AC
ProtectionOverload, Over Voltage, Over Temperature, Short Circuit

Related product manuals