Door Interface
The Door Interface (model DI-21, sold separately) provides a connection point for up to two Door Stations
(model DOOR1) and one telephone line. When a doorbell button is pressed or an inbound phone call is
sensed, all active zones are muted, and a unique music le is played (use one of our provided MP3 les or
replace with your own). Door Stations allow for convenient communication between any inside zone and
a front and/or back door. The zone that “answers the door” is put in a one-to-one communication with the
Door Station.
The DI-21 is also required to enable Phone-to-Zone (see pages 18-19) in place of using a second/back
door. Additional detail is provided on our website and in the manual provided with the DI-21.
Lync Controller
SD
CARD
AC 120V~60Hz
FUSE T2AL/250V
Power Consumption: 160W
ROUTED IR OUT
Source 7
SOURCE INPUT
KEYPAD PORTS
7
8
9
10
11
12
MP3
L
ZONE 1 PREOUT ZONE 2 PREOUT ZONE 3 PREOUT ZONE 4 PREOUT ZONE 5 PREOUT ZONE 6 PREOUT
MONO STEREO MONO STEREO MONO STEREO MONO STEREO MONO STEREO MONO STEREO
R
LRLR
LRLR
LR LR LR LR
LRLRLR
R
L
43
2
1
56
IR IN
RS232
INTERFACE
GLOBAL
IR OUT
12V/DC
TRIGGER
100mA
IN OUT
System
TRIGGER
AC/DC 3-20V
Mute
Made in Ta iwan
CAUTION
To Prevent Electric Shock,
Do Not Remove Cover. No
User-Serviceable Parts Inside,
Refer Servicing To Qualified
Service Personnel.
WARNING
To Prevent Fire Or Shock
Hazard, Do Not Expose This
Unit To Rain Or Moisture.
FIXEDVA RIABLE
IR IN
Door
Interface
or
Door Station
DI-21
Cat5/6
Cat5/6
Standard
Phone
Cable
Power
Adaptor
Input
RJ11
Analog Phone Line
(will not work with
a digital line)
Adding a gateway to your Lync controller makes the system capable of being
controlled by our free HTD Lync app over your existing WiFi network. The gateway
connects to the RS232 Interface using a cable included with the gateway. RS232 is
a standard commonly used in the home automation industry. Detailed instructions
are included with your gateway and are also available online.
Connecting a Gateway
Power
123456 123456
789101112
Zone Status Source Signal Strength
AC 120V~60Hz
FUSE T2AL/250V
DOOR INTERFACE
Power Consumption: 160W
ROUTED IR OUT
SOURCE INPUT
KEYPAD PORTS
7
8
9
10
11
12
MP3
L
ZONE 1 PREOUT ZONE 2 PREOUT ZONE 3 PREOUT ZONE 4 PREOUT ZONE 5 PREOUT ZONE 6 PREOUT
MONO STEREO MONO STEREO MONO STEREO MONO STEREO MONO STEREO MONO STEREO
R
LRLR
LRLR
LR LR LRLR
LRLRLR
R
L
43
2
1
56
IR IN
RS232
INTERFACE
GLOBAL
IR OUT
12V/DC
TRIGGER
100mA
IN OUT
System
TRIGGER
AC/DC 3-20V
Mute
Made in Ta iwan
CAUTION
To Prevent Electric Shock,
Do Not Remove Cover. No
User-Serviceable Parts Inside,
Refer Servicing To Qualified
Service Personnel.
WARNING
To Prevent Fire Or Shock
Hazard, Do Not Expose This
Unit To Rain Or Moisture.
FIXEDVA RIABLE
IR IN
SOURCE 7

Related product manuals