EasyManua.ls Logo

Huawei AR500 - Ar2504-D-H

Huawei AR500
141 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Item Specification
AC power input
l Rated voltage: 100 V AC to 240 V AC, 50/60 Hz
l Maximum voltage range: 90 V AC to 264 V AC, 47 Hz to 63 Hz
DC power input
l Rated voltage: 110 V DC to 250 V DC
l Maximum voltage range: 88 V DC to 300 V DC
Maximum output
power
l One power module configured: 60 W
l Two power modules configured: 120 W
Interface density
Console interfaces 1
USB 2.0 interfaces 1
DO interfaces 1
ETH interfaces 1
Service interfaces
(standard
configuration)
l Four GE electrical interfaces
l Four GE combo interfaces
l Two 10GE optical interfaces
Environment parameters
Operating
environment
temperature
-40°C to +65°C (-40°F to +149°F)
NOTE
In compliance with IEC60068-2-1-2007 and ETSI EN 300 019-2-3
V2.2.2:2003, the router can operate reliably for 24 hours in a temperature
range of -40°C to +70°C (-40°F to +158F).
Storage
temperature
-40°C to +85°C (-40°F to +185°F)
Operating relative
humidity
5% to 95%, noncondensing
Operating altitude < 5000 m (16404 ft.)
Part number 02350RBM
7.5.3 AR2504-D-H
Technical Specifications
Table 7-27 lists technical specifications of the AR2504-D-H router.
Huawei AR500&AR510&AR530&AR550&AR2500
Series Industrial Switch Routers
Product Description
7 Technical Specifications
Issue 02 (2016-11-25) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
125