Table 6-24 Levels on DI lines
Switch DI Lines 0, 1, 2 DI Lines 3, 4, 5
Open High level High level
Closed Low power Low power
Switch
Switch
3.3V
DI
DI/DO interface
DI
3.3V
DIDO0,DIDO1,DIDO2
DIDO3,DIDO4,DIDO5
GND
l Use of the DO lines:
– Connection of any of DO lines 0, 1, and 2: Connect the positive pole of an LED to
the 3.3 V power supply line a current-limiting resistor, and connect the negative
pole of the LED to a DO line.
– Connection of any of DO lines 3, 4, and 5: Connect the positive pole of an LED to a
DO line and connect the negative pole to the GND line.
Determine the levels on the DO lines according to Table 6-25.
Table 6-25 Levels on DO lines
LED
DO Lines 0, 1, 2 DO Lines 3, 4, 5
On Low power High level
Off High level Low power
Huawei
AR500&AR510&AR531&AR550&1500&AR2500
Industrial Switch Routers
Hardware Description
6 Cables