EasyManua.ls Logo

Huawei ATN 905 - Page 45

Huawei ATN 905
78 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Figure 4-6 Core connections of the management cable connected to the NM network interface
or NM serial interface
1 2 3 4 5 6 7 8
Pos.1
Pos.6
Pos.5
Pos.9
1 2 3 4 5 6 7 8
ETH/OAM
1 Transmit positive of the NM interface
2 Transmit negative of the NM interface
3 Receive positive of the NM interface
4 Grounding end of the Console interface
5 Receive end of the Console interface
6 Receive negative of the NM interface
7 Unspecified
8 Transmit end of the Console interface
NM network interface
(terminal side)
NM serial interface
(terminal side)
Table 4-10 Descriptions of the alarm indicator (ALM)
Status Description
Indication
On (red) An equipment-level critical alarm is reported.
On (yellow) An equipment-level major or minor alarm is reported.
Off No equipment-level alarm is reported.
Table 4-11 Descriptions of the working status indicator (STAT)
Status Description
Indication
On (green) The device is running properly.
On (red) A device hardware fault has occurred.
ATN 905 Multi-service Access Equipment
Product Description 4 Hardware Structure
Issue 01 (2013-05-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
39

Table of Contents