NO TE
The parameter settings vary depending on the SmartLogger version. Set the parameters
based on requirements.
Step 2 Choose Maintenance > System Maint., and import the conguration of the old
SmartLogger to the new SmartLogger3000.
Figure 5-2 Import
congurations.
NO TICE
When a faulty SmartLogger3000 is replaced with a new SmartLogger3000, the full
conguration le does not contain certicate-related les. After the full
conguration le is imported, you need to reload a third-party certicate if
required.
Step 3 (Optional) Choose Maintenance > Device Mgmt. > Data Re-collection to
synchronize inverter information.
NO TE
In a faulty SmartLogger2000 or SmartLogger1000A is replaced with a SmartLogger3000,
the full conguration le exported from the SmartLogger2000 or SmartLogger1000A does
not contain the performance data or energy yield information of inverters. Synchronize the
data if required.
FusionSolar Smart PV Solution-Device Replacement