5.2.2 pRRU3901 Specifications
Item
Specifications
Dimensions
Height (mm)
Width (mm)
Depth (mm)
230
230
50
Weight
≤ 3 kg
Input voltage
AC/DC power: 100 V AC to 120 V AC; 200 V AC to 240 V AC
PoE: -36 V DC to -60 V DC
Transmission port
Two FE/GE electrical ports
Power consumption
With one RF card: ≤ 30 W
With two RF cards: ≤ 50 W
5.3 Environment Requirements
Item
Specifications
Operating temperature
RHUB: 5ºC to +50ºC
pRRU3901:
Installed on a wall: C to +45ºC
Installed on a ceiling: 5ºC to +40ºC
Storage temperature
40ºC to +70ºC
Relative humidity
5% RH to 95% RH
Absolute humidity
1 g/m
3
to 30 g/m
3
Operating pressure
70 kPa to 106 kPa
Protection rate
IP20
Operating environment
EUROPEAN ETS 300 019-1-3 Temperature-controlled
locations Class 3.2
Storage environment
ETSI EN300019-1-1 V2.1.4 (2003-04) class1.2 "Weather
protected, not temperature-controlled storage locations"
Transport environment
ETSI EN300019-1-2 V2.1.4 (2003-04) class 2.3 "Public
transportation"
Anti-seismic
performance
IEC 60068-2-57 (1999-11) Environmental testing Part 2-57:
Tests Test Ff: Vibration Time-history method
YD5083-99: Interim Provisions for Test of Anti-seismic
Performance of Telecommunications Equipment (telecom
industry standard in the People's Republic of China)
GR63 5.4.1 zone4: NEBS
TM