Common Faults and Troubleshooting
The PV string cables are 
connected reversely 
during the SUN2000 
installation.
Wait until the solar irradiance declines at night and the 
PV string current reduces to below 0.5 A. Then, turn off 
the two DC switches, remove the positive and negative 
connectors, and correct the polarity of the DC input 
power cable.
Appendix 1: Grid Codes (SUN2000-50KTL)
No. Grid Code Description No. Grid Code Description
1 CHINA-MV480
China medium-voltage 
power grid (480 V)
2
IEC61727-
MV480
IEC61727 medium-
voltage power grid (50 
Hz)
3 KOREA-MV480
South Korea medium-
voltage power grid (480 
V)
4
ABNT NBR 
16149_MV480
Brazil medium-voltage 
power grid (480 V)
Appendix 2: Grid Codes (SUN2000-50KTL-C1)
No. Grid Code Description No. Grid Code Description
1 CHINA_MV500
China medium-voltage 
power grid (500 V)
2
IEC61727-50 
Hz-MV500
India medium-voltage 
power grid (500 V)
Grid codes are subject to change. The listed codes are for your reference only.